Fan TEB-3 / TN-3
Symbols used
Symbol indicates possible hazards.
Note containing information and tips.

Safety instructions

The unit must only be installed and re-
paired by an expert.
The installation of the appliance and its connec-
tion to an electricity supply must comply with
the technical and administrative regulations of
the respective country of use (e.g. EN 1648,
VDE 0100, Part 721 or IEC 60364-7-721). Na-
tional regulations and rules must be followed.
In view of the proximity to a heater, only heat-
proof cables (suitable for at least 100 °C) may
be used.
Before connecting or disconnecting cables,
please ensure that the power supply has been
6
disconnected at all poles. Also disconnect the
mains or connector plug to the trailer vehicle if
applicable and disconnect the battery. Switch-
ing off at the control panel is insufficient.

Intended use

Fan for installation on a Truma S 3004 or S 5004 heater.

Installation instructions

Installing the fan on an installation box
Fig. A (installation example S 3004)
Remove the pre-cut cover on the back of the installation box.
Screw in or loosen screws (1 – B 3.5 x 19) enough to enable
the mounting brackets of the fan to be fitted. Mount the fan
and tighten screws.
Installing the fan on an installation box
for two fans
A special installation box for connecting two fans is available
for the S 5004 / S 5004 E (NL) heater. Installation is identical
to that of the version with a single fan.