Installation
instructions
Installation and repair of
the Truma-Multivent fan
may only carried out by an
expert.
When using control panels
which are specific to the
vehicle or manufacturer,
the electrical connection
must be effected in accor-
dance with Truma inter-
face specifications.
For connection of the
fan with air duct ÜR
65 mm dia. to the installation
box EKM or the rear panel
with heat deflector, a intake
nozzle DM (fig. D: Part no.
40670-00) is required.
1. fig. C: Fix the fan (1) with
two screws (2) to the floor,
to the wall, to the ceiling
etc. (the fan works in all
positions).
2. Push the ducts ÜR 65 mm
dia. for the warm air distribu-
tion into the connection fit-
tings and fasten with self
tapping screws (3).
6
3. Fig. C: Choose a place for
the control panel (5) in a posi-
tion which is easy to view.
If it is not possible to in-
stall the control panel
flush with the surface, Truma
can provide a surface-mount-
ing frame (6) on request, as a
special accessory (Part no.
40000-52600).
4. Lay the cable (4) from the
fan (1) to the place intended
for the operating unit (5).
If required, use a cable 3 x
0.75 mm
2
as an extension.
5. Drill a 55 mm diameter
hole. Feed the connection ca-
ble from the fan (4) and
12 V lead (7) from behind
through the hole in the wall,
and connect it to the operat-
ing unit in accordance with
the connection diagram
(fig. E).
1 = white
2 = brown
3 = green
– = negative lead
+ = positive lead 12 V
Fit the rear cover cap (8) as a
stress-relieving device, then
secure the control panel (5)
with 4 screws (9) and fit the
cover frame (10).
As a finish for the cover
frame, Truma can pro-
vide as special accessories
a set of side pieces (11 –
Part no. 34000-61200).
Connect fan to fused vehicle
power supply (central electri-
cal system 5 – 10 A) using a
cable 2 x 0.75 mm
2
. When
connecting directly to the
battery, always fuse the posi-
tive and negative lead.
Secure all cables with cable
clips.
When power supplies
are being used, it must
be noted that the output volt-
age is between 11 V and
15 V and the alternating
current ripple is < 1.2 Vss.

Function test

After installation, check all
the functions in accordance
with the Operating Instruc-
tions.
The operating instructions
must be handed over to the
user!