DELTAV<n> <nrf>
DELTAI<n> <nrf>
DELTAV<n>?
DELTAI<n>?
INCV<n>
INCV<n>V
DECV<n>
DECV<n>V
INCI<n>
DECI<n>
OP<n> <nrf>
OP<n>?
TRIPRST
LOCAL
IFLOCK
IFLOCK?
IFUNLOCK
LSR<n>?
LSE<n> <nrf>
LSE<n>?
System and Status Commands
*CLS
EER?
*ESE <nrf>
Set the output <n> voltage step size to <nrf> Volts
Set the output <n> current step size to <nrf> Amps
Returns the output <n> voltage step size
The response is DELTAV<n> <nr2><rmt> where <nr2> is in Volts.
Returns the output <n> current step size
The response is DELTAI<n> <nr2><rmt> where <nr2> is in Amps.
Increment the output <n> voltage by the step size set for output <n>
Increment the output <n> voltage by the step size set for output <n> and
verify.
Decrement the output <n> voltage by the step size set for output <n>
Decrement the output <n> voltage by the step size set for output <n> and
verify
Increment the output <n> current limit by the step size set for output <n>
decrement the output <n> current limit by the step size set for output <n>
set output <n> on/off where <nrf> has the following meaning: 0=OFF, 1=ON
Returns output <n> on/off status.
The response is <nr1><rmt> where 1 = ON, 0 = OFF.
Attempt to clear all trip conditions.
Go to local. This does not release any active interface lock so that the lock
remains with the selected interface when the next remote command is
received.
Request interface lock. This command requests exclusive access control of
the instrument. The response is 1 if successful or –1 if the lock is
unavailable either because it is already in use or the user has disabled this
interface from taking control using the web interface
Query the status of the interface lock. The return value is 1 if the lock is
owned by the requesting interfaced instance; 0 if there is no active lock or –1
if the lock is unavailable either because it is already in use, or the user has
disabled this interface from taking control using the web interface.
Release the lock if possible. This command returns the value 0 if successful.
If this command is unsuccessful –1 is returned, 200 is placed in the
Execution Register and bit 4 of the Event Status Register is set indicating
that there is no authority to release the lock.
Query and clear Limit Event Status Register <n>.
The response is <nr1><rmt>. See Status Reporting section for details.
Set the value of LSE<n>, Limit Event Status Enable Register <n>, to <nrf>
Return the value of LSE<n>, Limit Event Status Enable Register <n> -
response is <nr1><rmt>
Clear Status. Clears the Status structure. This indirectly clears the Status
Byte Register.
Query and clear Execution Error Register. The response format is nr1<rmt>.
Set the Standard Event Status Enable Register to the value of <nrf>
33