Specifications
Power supply ................................................................................................... 100-240Vac 50/60Hz
Consumption ............................................................................................................................ 80W
Light source ........................................................ 8x 10W LED (2x red, 2x green, 2x blue, 2x white)
Single beam angle ........................................................................................................................ 4°
Dimensions ....................................................................................................... 298 x 149 x 262mm
Weight ..................................................................................................................................... 3.5kg
Installation
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid
vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure
and able to support a weight of 10 times of the unit's weight. Also always use a safety cable that can hold 12 times
the weight of the unit when installing the fixture.
The equipment must be fixed by professionals at a place where is out of the reach of people and where nobody can
pass by or under it.
ORIENTATION
This fixture may be mounted in any position provided there is adequate room for ventilation.
RIGGING
The LED moving head provides a unique mounting
bracket assembly that integrates the bottom of the base,
the included 'omega bracket' and the safety cable rigging
point in one unit (see the illustration on the right).When
mounting this fixture on a truss, be sure to use an
appropriate clamp with the included omega bracket using
a M10 screw fitted through the center hole of the 'omega
bracket'. As an added safety measure, be sure to attach
at least one properly rated safety cable to the fixture
using one of the safety cable rigging points integrated in
the base assembly.
Fuse Replacement
Disconnect the power cord before replacing a fuse and always replace with the same type fuse.
With a flat head screwdriver wedge the fuse holder out of its housing.
Remove the damaged fuse from its holder and replace with exactly the same type of fuse.
Insert the fuse holder back in its place and reconnect power.
Data Cabling
To link fixtures together you must use data cables. If you choose to create your own cable, please use data-grade
cables that can carry a high quality signal and are less prone to electromagnetic interference.
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
©Copyright LOTRONIC 2016
QUAD8-FX
Page 3