Télécharger Imprimer la page

Tristar SZ-1913 Mode D'emploi page 6

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
Operation and maintenance
Remove all packaging of the device.
Check if the voltage of the appliance corresponds to the main voltage of your home.
Rated voltage : AC220-240V 50Hz.
This vacuum is not designed to collect liquids and sharp items. Never vacuum hot ashes,
make sure it is fully cooled.
First use
Place the hose (no. 12) (with the side of the hose coupling) in the hose connection (no. 9) of
the vacuumcleaner. If you hear a click, the hoses is connected correct. Place the floor brush
(no. 13) on the telescopic tube (no. 11). The telescopic tube length can be made, according to
your wishes, by pressing the button down and push the tube to extend or reduce. To
disconnect the hose press the button of the hose coupling. Use the button on the floor brush
for the desired position, with or without a brush on the bottom of the floor brush.
Always make sure that all the filters and the dust bag are correctly fitted before using the
appliance. Damaged or incorrectly fitted filters or dust bag may cause damage to the appliance.
Use
Pull the power cord totally out of the vacuum cleaner and place it into a wall outlet. Press the
on/off switch (no. 3) to start your vacuum cleaner.
The suction power regulator (no.1) controls the suction power.
To turn the unit off, press the on/off switch. Unplug the power cord and press the cable rewind
button (no. 2). You can use the storage clip (no. 5) at the back of the device to store the
vacuum bar.
Cleaning and maintenance of the device
Always remove the plug from the outlet when the device is not used, the filters are cleaned or
the dust bag will be replaced.
Replace of the dust bag.
You need to replace the dust bag when the dust bag full indicator (no. 8) lights.
Do this immediately otherwise it loses much of its suction power.
Disconnect the hose from the hose connection (no 9).
Open the unit by pulling the handle for opening dust
bag compartment (no. 10). The valve is open.
Remove the black dustbag holder, by pulling it up.
Slide the dustbag out of the dustbag holder. Place the
new dust bag in the dustbag holder and replace the
dustbag holder into the device. Close the lid of the
compartment and put the hose in the hose connection.
.
11
Cleaning of the filters.
UK
To ensure the best suction of the vacuum cleaner, you should clean the filters at the back (the
exhaust filter) and behind the bag (inlet filter) regularly.
Cleaning the inlet-filter
Disconnect the hose from the hose connection (no. 9). Open the unit by the handle for opening
dust bag compartment (no.10). The valve is open. Remove the black dust bag holder by
pulling it up. Remove the filter from the filter holder. Clean the filter with warm water, let the
filter dry completely before replacing it. The filter is not dishwasher safe.
Cleaning of the exhaust filter
Pull out the air outlet cover (no. 6) at the back of the device off. Remove the Hepa filter from
the filter holder. Clean the Hepa filter with warm water, let the Hepa filter dry completely before
replacing it. The Hepa filter is not dishwasher safe.
The vacuum cleaner and the other parts you can use a damp cloth to decline.
Never immerse the device in water or other liquid.
Never use the vacuum with a wet filter! This may cause an electric shock and
the unit may malfunction.
12

Publicité

loading