Unpack the Gas Convection Oven immediately after receipt. Remove the Gas Convection Oven from the
crate; remove all packaging on and surrounding the unit and be certain to remove all protective plastics and
residues from all surfaces. Make sure that all parts provided located. Equipment must have the legs and/or
casters properly installed before use. Before using this equipment it must be cleaned and dried thoroughly.
INSTALLATION
NOTE: it is vital that the purchaser of this equipment post in a prominent location instructions to be followed in
the event that the user smells gas. This information shall be obtained by consulting the local gas supplier. The
purchaser of this equipment must post in a prominent location.
1. Read this manual thoroughly before installation and operation. DO NOT proceed with installation and
operation if you have any questions or do not understand anything in this manual. Contact your local
representative or Kintera first.
2. Select a location for the Gas Convection Oven that has a level, solid, nonskid surface that is
nonflammable and away from water hazards or sinks, and is in a well-lighted work area away from
children and visitors.
3. This equipment MUST be installed under a proper ventilation as required by local code.
Local codes regarding installation and ventilation vary greatly by area. The
National Fire Protection Association states in its NFPA 96 latest edition (see NFPA page at the
beginning of this manual) that local codes are "authority having jurisdiction" when it comes to
requirements for installation of equipment. Therefore, installation should comply with all local
codes.
4. Attach legs into permanently fastened nuts on the four corners of the unit and tighten. Legs must be
installed to adequately provide proper ventilation to the unit.
5. Level unit to the center oven rack by adjusting the four feet and tighten securely. The adjustable
feet have an adjustment of one inch. Do not slide unit with legs mounted. Lift if necessary to move
unit.
6. The supplied gas pressure regulator is factory set at 4" Natural Gas W.C. or 10" Propane Gas.
7. THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACE ONLY.
Noncombustible clearances: 2" sides (152 mm), 2" rear (152 mm), 6" floor (152 mm).
8. Do not obstruct the flow of combustion and ventilation air under the unit by the legs or behind the unit
by the flue.
9. There must be adequate clearance for removal of the front and right side panel. All major parts
except the burners are removable through the front if the gas is disconnected.
10. Pipe threading compound must be resistant to the action of liquefied petroleum gas.
DO NOT USE TEFLON TAPE.
DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap
and water solution before operating the unit.
The installation of this appliance must conform to local codes, or in the absence of local codes, the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA
B149.1, as applicable.
The appliance and its individual shut off valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of ½ PSI (3.5kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual
shut off valve during any pressure testing of the gas supply piping system at test pressures equal to
less than ½ PSI (3.5kPa).
Clearance and positioning around the appliance: This appliance must be installed adjacent to
non-combustible surfaces only with a minimum spacing of six (2") inches from sides and two (2)