RIB SUPER 8000 FAST Mode D'emploi page 31

Operateur irreversible pour portails coulissantes
Masquer les pouces Voir aussi pour SUPER 8000 FAST:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

A - CONNEXIONS
J1
L1 - N
230Vac 50/60Hz POWER SUPPLY (120Vac/60Hz UPON REQUEST)
BLINKER (40 W MAX.)
J2
U
MOTOR COMMON CONNECTION
V-W
MOTOR PHASES CONNECTIONS
J3
PED. BUTT.
PEDESTRIAN OPENING CONTACT (NO)
A+ TEST
+24Vdc SAFETY STRIP SELF-TEST POWER SUPPLY
LSC
CLOSE LIMIT SWITCH THAT CUTS OFF THE MOTOR IN CLOSING
COM
LIMIT SWITCH COMMON CONTACT
LSO
OPEN LIMIT SWITCH THAT CUTS OFF THE MOTOR IN OPENING
J4
STOP
STOP CONTACT (NC)
OPEN
OPENING CONTACT (NC)
CLOSE
CLOSING CONTACT (NC)
K. BUTT.
SINGLE PULSE CONTACT (NO)
A+
ACCESSORIES POWER SUPPLY +24Vdc
A-
ACCESSORIES POWER SUPPLY -24Vdc
SIGNAL
GATE OPEN INDICATOR 24Vdc
COM
COMMON CONTACT (common line for all the command and safety
inputs)
EDGE NC
SAFETY STRIP CONTACT (NC)
J5
AERIAL
RADIO ANTENNA
COM
COMMON CONTACT (common line for all the command and safety
inputs)
PHOTO NC
PHOTOCELLS CONTACT (NC)
J6
PROBE
-
J7
ENCODER
-
J8
RADIO
CONNECTOR FOR EXTERNAL RADIO RECEIVER 24Vdc
S3
PROG.
PROGRAMMING BUTTON
TR1
LOW SPEED
-
TR2
TORQUE
-
DO NOT REMOVE ANY JUMPER! OTHERWISE THE OPERATOR WILL
SW
RADIO
NOT WORK!
SW S1
DO NOT REMOVE THE JUMPER! OTHERWISE THE OPERATOR WILL
NOT WORK!
SW1
DIP-SWITCHES
SW2
SW3
L1
L2
L3
N
3-PHASE LINE
Install a
Residual Current Circuit
Breaker like
ABB F204A-25/0,3
J5
TR1
TR2
J4
SW
S1
J3
J2
J1
S1-CRX
AC07097
31
S3
J7
J6
NC: NORMALLY CLOSED CONTACT
NO: NORMALLY OPEN CONTACT
G
B
SW
RADIO
RADIO
J8
SW1
SW2
SW3