GiBiDi BE24 Mode D'emploi page 22

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

22
UK
14 - FLASHING LIGHT SIGNALS SUMMARY
Photo 2 intercepted in stand-by
in presence of START command
Edge intercepted in stand-by
in presence of START command
Edge intercepted in pause in presence of
START command or at the closing beginning
Low Battery before closing (21V).
Low Battery before opening or closing(16V).
15 - TROUBLESHOOTING
The gate does not move after a START
command.
The gate moves slowly.
Transmitter range is short.
The gate does not fully open/close.
The gate moves slowly during opening.
Meaning
Opening
Closing
Ÿ
terminals 19-20-21.
Ÿ
Ÿ
Ÿ
Check the control board is not running on battery.
Check terminals 26-27 screws are tight.
Check and replace transmitter battery.
Check the motor and encoder connections.
The first maneuvre after a power failer is slowed and with automatic logic.
Signal
0,8s ON, 0,8s OFF continuous
0,4s ON, 0,4s OFF continuous
5 fast flashings
3 slow flashings
3 slow flashings
4 seconds slow flashing
4 seconds slow flashing
Check that L3, L4 and L5 are off; if not, check the devices connected to
Check fuses.
Check that the battery voltage is not below 22VDC.
If L7 is blinking fast, learning procedure must be executed.
BE24
Effect
The gate is opening
The gate is closing
When released it opens
Blocked closed door
Blocked open door
Blocked open door
Blocked door

Publicité