Storing the device
1. Store the suction hose and mains cable as shown in
the illustration.
Illustration F
2. Store the device in a dry room and secure it against
unauthorised use.

Transport

CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during transporta-
tion.
1. Remove the suction hose with floor nozzle from the
support. Carry the device by the carrying handle and
suction pipe.
2. Load the device by the chassis handle and push
handle.
3. Pull the device behind you via the push handle for
transporting over longer distances.
4. When transporting the device in vehicles, secure it
to prevent it from slipping or overturning in accord-
ance with the respective valid guidelines.

Storage

CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during storage.
The device may only be operated indoors.

Care and service

DANGER
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the mains plug.
Replacing the flat fold filter
1. Open the filter cover.
2. Remove the flat fold filter.
3. Fit the new flat fold filter. During insertion, ensure
that the flat fold filter is flush on all sides.
4. Close the filter cover until it audibly latches into
place.
Cleaning the electrodes
1. Unlock and remove the suction head.
2. Clean the electrodes and the gap between the elec-
trodes with a brush.
3. Fit and lock the suction head.

Troubleshooting guide

DANGER
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the mains plug.
Suction turbine does not start up
1. Check the socket and the power supply fuse.
2. Check the mains cable, mains plug and electrodes
on the device.
3. Switch on the device.
Suction turbine switches off
1. Empty the container.
Suction turbine does not switch on again after emp-
tying the container
1. Switch off the device and wait for 5 seconds. Switch
on the device.
2. Clean the electrodes and the gap between the elec-
trodes with a brush.
Suction power decreases
1. Remove any blockages from the suction nozzle,
suction pipe, suction hose or flat fold filter.
2. Change the filled paper filter bag.
3. Press the semi-automatic filter dedusting button 5x
with the device switched on.
4. Correctly engage the filter cover.
5. Replace the flat fold filter.
Escaping dust when vacuuming
1. Check that the flat fold filter is correctly fitted and
correct if necessary.
2. Replace the flat fold filter.
The automatic switch-off mechanism (wet vacuum
cleaning) does not trigger
1. Clean the electrodes and the gap between the elec-
trodes with a brush.
2. Continuously monitor the filling level when vacuum-
ing non-conductive liquids.
Semi-automatic filter dedusting not working
1. Suction hose not connected.
Semi-automatic filter dedusting does not switch off
1. Contact Customer Service.
Semi-automatic filter dedusting cannot be switched
on
1. Contact Customer Service.
Customer Service department
If the malfunction cannot be corrected, the device must
be checked by the Customer Service department.
The warranty conditions issued by our relevant sales
company apply in all countries. We shall remedy possi-
ble malfunctions on your appliance within the warranty
period free of cost, provided that a material or manufac-
turing defect is the cause. In a warranty case, please
contact your dealer (with the purchase receipt) or the
next authorised customer service site.
(See overleaf for the address)

Accessories and spare parts

Only use original accessories and original spare parts.
They ensure that the appliance will run fault-free and
safely.
Information on accessories and spare parts can be
found at www.kaercher.com.