Bühler technologies EGK 2-19 Notice De Montage page 9

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
EGK 2-19 (+)
When the moisture detector (optional) is installed, an alarm is
activated if moisture is still present in the prepared sample
gas or a cable break is detected. It does not differentiate if the
alarm / cable break was triggered by moisture detector 1 or 2.
This information, however, appears in the display.
If the option "temperature signal" is built in, the unit has a
signal to indicate the actual cooler temperature. The option
"Moisture detector" includes the option "Temperature sig-
nal".
Fig. 2: 12-pin PHÖNIX connector
A Moisture detector status
(residual moisture) (op-
tion)
B Cooler status (excess or
insufficient temperature)
5 Operation and control
NOTICE
The device must not be operated beyond its specifications.
After switching on the cooler the block temperature will be
displayed. The display will flash until the block temperature
has reached the preset target value (± adjustable alarm
range). The status contact is in the Alarm position.
Once the target temperature range has been reached, the
temperature will continuously be displayed and the status
contact switches over.
If the display flashes during operation or an error message ap-
pears, please refer to bullet "Troubleshooting".
Please refer to the data sheet for performance data and max-
imum ratings.
BX450010 ◦ 10/2018
C Analogue temperature
output (4-20 mA) (op-
tional)
D Equipment dimensions:
Connection for the 4-20
mA signal line shielding
5.1 Use of menu functions
Overview of the operational principal:
Use this short description if you have experience with the
device.
Operation is carried out by only the keys with the following
functions:
Key
• Switch from measurement display to main
menu
• Selection of the display menu item
• Accepting the changed value or selection
• Switch to the upper menu item
• Increase of the value of switching the selection
• Temporary display of the alternative measure-
ment display (if option is installed)
• Switch to lower menu item
• Decrease of the value of switching the selection
• Temporary display of the alternative measure-
ment display (if option is installed)
Function
Bühler Technologies GmbH
9

Publicité

Chapitres

Table des Matières
loading

Table des Matières