Print Settings; Label Layout - Carl Valentin SPECTRA 107/12 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 54
Spectra

Print settings

Keys:
Key:
Key:
Key:
Key:
Key:

Label layout

Keys:
,
Key:
Key:
Key:
Key:
Key:
Key:
88
Speed:
Value range: 50 mm/s ... 300 mm/s (see the technical data).
Contrast:
Value range: 10% ... 200 %.
Transfer ribbon control:
Examination if the transfer ribbon roll is to end or if the ribbon was torn at the unwinding roll.
Off: The ribbon control is deselected, i.e. the printer continues without an error message.
On: The ribbon control is selected, i.e. the current print order is interrupted and an Error
Message appears at the printer display.
strong sensibility: The printer reacts immediately to the end of the transfer ribbon.
weak sensibility: The printer reacts at approx. 1/3 more slowly to the end of the transfer
ribbon.
Y displacement:
Indication of initial point displacement in mm. The label is moved vertically.
Value range: −30.0 ... +90.0.
X displacement:
Indication of displacement in X direction. The fields on the label are moved.
Value range: −90.0 ... +90.0.
Tear off:
The standard value of tear off offset is 12 mm.
Value range: 0 ... 50.0 mm.
Label:
Minimum height: 5 mm (dispenser mode: 25 mm).
Gap:
Minimum value: 1 mm.
Column printing:
Indication of width of one label as well as how many labels are placed side by side.
Measure label:
Press key
to start measuring
Type of label:
Generally adhesive labels are set. In case you would like to use continuous labels, you have to
select this in the menu.
Material:
Selection of the used print materials.
Photocell:
Selection of the used photocell.
Scan position (AP):
Entry of percental label length by that the label end is searched. Marks onto the label can be
skipped.
English

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Spectra 108/12Spectra 160/12Spectra 162/12Spectra 216/12

Table des Matières