AC CURRENTS
A AC
Voltage (2)
drop
Digital
resolution
Bargraph
resolution
Accuracy (4)
Protection (3)
(1) 4000 count display limited to 10 A Between 5A and 10A, to avoid
overheating, limit the operating time to 10 minutes
(2) Voltage drop at the terminals for 40mA, 400mA, 10A
(3) Permitted overloads :
600 mA for 30 seconds for the 400 mA range
15 A for 30 seconds for the 10 A range
(4) Use on frequency : 40Hz to 500Hz
40 mA
600 mV
10 µA
1 mA
± 1.5 % reading ± 2 counts
Fuse 0.4 A HBC
28
400 mA
4,5 V
100 µA
10 mA
± 2 counts
Fuse 12 A HBC
10 A
(1)
600 mV
10 mA
1 A
± 2 % R