3.2.1. FILLING THE JACKET (MODELS PMKIG... .)

Warning! : The water level in the jacket must be checked each time before lighting.
Warning! : It is advisable to use softened water to fill the jacket!
− Open the level tap on the front of the appliance.
− Unscrew the filling cap on the safety valve unit. The latter is on the right of the
appliance surface (see figure "Size of appliance and position
of connections ").
− Reposition the tap (an external hole is available) on the
external pin of the relief valve.
− This operation is required to prevent water bubbles from
forming in the jacket during water loading. Water bubbles
would not make it possible to reach a correct water level in the
jacket.
− Fill with softened water (the capacity of the jacket is stated in the paragraph "Technical
data").
− When water flows out of the level tap, close it and screw back on the safety unit cap.