Junction Box Installation - Continental Fireplaces CHD35NT Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

42
8.3

JUNCTION BOX INSTALLATION

Remove the two screws that secure the junction box assembly to the outer
A.
shell on the left side of the fi re place and remove the junction box assembly.
EN
Remove the one screw that secures the junction box to the junction box plate
B.
and slide off the clip.
Route the supply wire through the 7/8" (22mm) hole of the junction box plate
C.
with a box connector (not supplied).
Connect the 120 volt supply wire to the receptacle as per the CSA C22.1
D.
Canadian Electrical Code in Canada or the ANSI/NFPA 70-
1996 National Electrical Code in the United States.
Once the wiring is complete, re-install the junction box to
E.
the junction box plate and re-secure the screw that was
removed in step B.
Re-install the junction box assembly by reversing step A
F.
making sure all plugs are secure in the junction box.
NOTE: If the appliance is already installed inside the enclosure, you can access the junction box from
inside the appliance by removing the burner base assembly, see "ACCESSING THE BLOWER" section.
W415-1348 / A / 07.17.15
B
1
2
B
A

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Chd40ntChd46ntChd35ptChd40ptChd46pt

Table des Matières