5.1

MINIMUM CLEARANCE TO COMBUSTIBLES

COMBUSTIBLE FRAMING:
Sides, back, bottom and top
of the appliance
COMBUSTIBLE FINISHING:
Bottom
Sides
Bottom
Enclosure Top
Recessed Depth
Sides and bottom of the vent
pipe
Top of vent pipe
Ceiling
* HORIZONTAL VENT SECTIONS: A minimum clearance of 1" (25mm) at the bottom and sides and 2"
(51mm) at the top of the vent pipe in all horizontal runs to combustibles is required except for clearances in
appliance enclosures. Horizontal vent sections within enclosures require a minimum clearance of 9" (229mm)
at the top of the vent pipe. See "MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES" section. Use
fi restop spacer W010-1777 (supplied) where vent pipe penetrates combustible walls.
* VERTICAL VENT SECTIONS: A minimum clearance of 1" (25mm) all around the vent pipe on all vertical
runs to combustibles is required except for clearances in appliance enclosures. Vertical vent sections
within enclosures require a minimum clearance of 4" (102mm) to the sides of the vent pipe. See "MINIMUM
CLEARANCE TO COMBUSTIBLE ENCLOSURES" section. Use fi restop spacer W500-0367 (not supplied)
where vent pipe penetrates combustible ceilings or fl oors.
OUTSIDE
CHASE
F
Ref
35 3/4" (908mm)
A
61 1/2" (1562mm)
B
43 1/2" (1105mm)
C
14 13/16" (376mm)
D
30 3/4" (781mm)
E
20 3/4" (527mm)
F
0" to stand-offs
0" to front edge of the appliance
1 1/4" to front edge of the appliance
6 1/2" to front edge of the appliance
70" (1778mm) from the bottom of the appliance
20" (508mm)
1"* (25mm)
2"* (51mm)
62" (1575mm) from the bottom of the appliance
F
A
INSIDE
CHASE
A
2" 51mm
6" 152mm
4" 102mm
MINIMUM ENCLOSURE CLEARANCES
CHD35
40 3/4" (1035mm)
66 1/2" (1689mm)
47" (1194mm)
16 9/16" (421mm)
33 1/4" (845mm)
20 3/4" (527mm)
C
BACK WALL OF CHASE / ENCLOSURE
(INCLUDING ANY FINSIHING MATERIALS)
2" 51mm
4" 102mm
CHD40
D
E
A
B
CHD46
46 3/4" (1187mm)
72 1/2" (1842mm)
51 1/4" (1302mm)
18 11/16" (475mm)
36 1/4" (921mm)
20 3/4" (527mm)
W415-1348 / A / 07.17.15
29
EN

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Chd40ntChd46ntChd35ptChd40ptChd46pt