1.2
rating plate information
f i r e - p a r t s . c o m
These illustrations are for reference only. Refer to the rating plate on the appliance for accurate information.
TITLE: RATING PLATE, WHD31 (SB)
EVISION: A: UPDATED CSA DATE & DESCRIPTION || 09.08.17_C.L.
1.3
mobile home installation
This appliance must be installed in accordance with the manufacturer's instructions and the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home
Standard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas
indicated on the rating plate.
This mobile/manufactured home listed appliance comes factory equipped with a means to secure the appliance. Built
in appliances are equipped with 1/4" (6.4mm) diameter holes located in the front left and right corners of the base.
Use appropriate fasteners, inserted through the holes in the base to secure. For free standing products contact your
local authorized dealer / distributor for the appropriate securing kit. For mobile home installations, the appliance must
be fastened in place. It is recommended that the appliance be secured in all installations. Always turn off the pilot and
the fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior to lighting the
appliance, ensure that the logs are positioned correctly.
This appliance is certifi ed to be installed in an aftermarket permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certifi ed kit is used.
Conversion Kits
This appliance is fi eld convertible between Natural Gas (NG) and Propane (P).
To convert from one gas to another, consult your Authorized dealer/distributor.
note:
Conversion kits are not available for Vent Free appliances.
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2016, CERTIFIED TO / CERTIFIE
CSA 2.22-2016 VENTED DECORATIVE GAS APPLIANCE / L'APPAREIL À GAZ
DÉCORATIF VENTILÉ.
9700539 (WSL)
4001658 (NAC)
FOYER À GAZ VENTILÉS À ÉVACUATION
DIRECTE. HOMOLOGUE POUR INSTALLATION
DIRECT VENT VENTED GAS FIREPLACE
DANS UNE CHAMBRE A COUCHER, UNE
APPROVED FOR BEDROOM, BATHROOM &
SALLE DE BAIN ET UN STUDIO. APPROPRIÉ
BEDSITTING ROOM INSTALLATION.
POUR INSTALLATION DANS UNE MAISON
SUITABLE FOR MOBILE HOME
MOBILE SI SON INSTALLATION CONFORME
INSTALLATION IF INSTALLED IN
AUX EXIGENCES DE LA NORME CAN/CSA
ACCORDANCE WITH THE CURRENT
Z240MH SERIE DE MAISONS MOBILES
STANDARD CAN/CSA Z240MH SERIES GAS
EQUIPÉES AU GAZ, EN VIGUEUR AU CANADA
EQUIPPED MOBILE HOMES, IN CANADA OR
OU AUX ÉTATS-UNIS DE LA NORME DE
IN THE UNITED STATES THE
SECURITÉ ET DE CONSTRUCTION DE
MANUFACTURED HOME CONSTRUCTION
MAISONS MANUFACTURÉES, TITRE 24 CFR,
AND SAFETY STANDARD, TITLE 24 CFR,
SECTION 3280. DANS LE CAS OU CETTE
PART 3280. WHEN THIS US STANDARD IS
NORME D'ÉTATS-UNIS NE PEUT ÊTRE
NOT APPLICABLE USE THE STANDARD FOR
APPLIQUÉE, SE RÉFÉRER A LA NORME
RELATIVE AU CRITÈRE DE MESURES DE
FIRE SAFETY CRITERIA FOR
SECURITÉ CONTRE L'INCENDIE POUR LES
MANUFACTURED HOME INSTALLATIONS,
INSTALLATIONS DANS LES MAISONS
SITES AND COMMUNITIES, ANSI / NFPA
MANUFACTURÉS, LES SITES ET LES
501A.
FOR USE WITH BARRIER W565-0121.
COMMUNAUTÉS, ANSI/NFPA 501A.
FOLLOW THE INSTALLATION INSTRUCTIONS
UTILISER AVEC BARRIÈRE W565-0121. SUIVEZ
LOCATED IN THE INSTALLATION MANUAL.
LES INSTRUCTIONS D'INSTALLATION SE
TROUVENT DANS LE MANUEL D'INSTALLATION.
WHD31N
CWHD31N
CWHD31P
NATURAL GAS MODEL
0-4500ft
ALTITUDE / ELEVATION
20,000 BTU/hr
INPUT / ALIMENTATION
65.2%
P4
MANIFOLD PRESSURE: 10 INCHES W.C.(LP)
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG)
PRESSION AU COLLECTEUR: 10" D'UNE
PRESSION AU COLLECTEUR: 3.5" D'UNE
COLONNE D'EAU (PL)
COLONNE D'EAU(GN)
MIN SUPPLY PRESSURE: 11" W.C. (LP)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 11" D'UNE
PRESSION D'ALIMENTATION MIN: 4.5" D'UNE
COLONNE D'EAU (PL)
COLONNE D'EAU (GN)
MAX. SUPPLY PRESSURE: 13" W.C. (LP)
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 13" D'UNE
PRESSION D'ALIMENTATION MAX: 7" D'UNE
COLONNE D'EAU (PL)
COLONNE D'EAU (GN)
NOT FOR USE WITH SOLID FUEL/ UN COMBUSTIBLE SOLIDE NE DOIT
PAS ÊTRE UTILSÉ AVEC CET APPAREIL
CAUTION: FOR USE WITH GLASS DOORS
ATTENTION: UTILISER AVEC LES PORTES
CERTIFIED WITH THIS UNIT ONLY.
VITRÉES HOMOLOGUÉES SEULEMENT AVEC
WARNING: DO NOT ADD ANY MATERIAL TO
AVERTISSEMENT: N'AJOUTEZ PAS A CET
THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN
APPAREIL AUCUN MATÉRIAU DEVANT ENTRER
THAT SUPPLIED BY THE MANUFACTURER
EN CONTACT AVEC LES FLAMMES AUTRE QUE
WITH THE APPLIANCE.
CELUI QUI EST FOURNI AVEC CET APPAREIL PAR
THIS VENTED GAS FIREPLACE IS NOT FOR
USE WITH AIR FILTERS.
CE FOYER À GAZ VENTILÉS NE DOIT PAS ÊTRE
DECORATIVE PRODUCT: NOT FOR USE AS A
UTILISÉ CONJOINTEMENT AVEC DES FILTRES À
HEATING APPLIANCE
ELECTRICAL RATING: 115V.60HZ. LESS
PRODUIT DÉCORATIF: NE PAS UTILISER COMME
THAN 12 AMPERES
SPÉCIFICATIONS ÉLECTRIQUES : 115 V,
THE APPLIANCE MUST BE VENTED USING
THE APPROPRIATE WOLF STEEL VENT KITS.
60 HZ. MOINS DE 12 AMPÈRES.
SEE OWNERS INSTALLATION MANUAL FOR
L'APPAREIL DOIT ÉVACUER SES GAZ EN
VENTING SPECIFICS.
UTILISANT L'ENSEMBLE D'ÉVACUATION PROPRE
MINIMUM CLEARANCE TO COMBUSTIBLE
A WOLF STEEL. RÉFÉRER AU MANUEL
MATERIAL:
D'INSTALLATION DE PROPRIÉTAIRE POUR
MANTEL
11
FLOOR
0"
SIDES
7"
VENT TOP
2"
DÉGAGEMENTS MINIMAUX DES MATÉRIAUX
VENT SIDES/BOTTOM
1"
MANTEAU
11"
CÔTÉS
7"
CÔTÉS DE L'ÉVENT / ÉVENT INFÉRIEUR
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
SERIAL NUMBER
WHD31
/ NO. DE SERIE
note:
BLACK ON WHITE BACKGROUND WITH BLACK BORDER
The rating plate must remain with the appliance at all times. It must not be removed.
TITLE: RATING PLATE, WHD31 (SB)
DWG#: W385-1968
REVISION: A: UPDATED CSA DATE & DESCRIPTION || 09.08.17_C.L.
DATE: 06.11.14
GARDEZ LE BRÛLEUR ET LE COMPARTIMENT DES
CONTRÔLES PROPRES. CONSULTEZ LE MANUEL
4001657 (NGZ)
4001659 (WUSA)
KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE
INSTALLATION AND OPERATING INSTRUCTIONS MANUAL.
Hot while operating. Do not touch. Severe burns may
result. Keep children, clothing, furniture, gasoline or
AVERTISSEMENT:
L'appareil est chaud pendant son fonctionnement. Les
enfants, les vêtements, les meubles, l'essence et autres
liquides qui émettent des gaz volatils inflammables
POUR
"This appliance is only for use with the type(s) of gas indicated on the
rating plate and may be installed in an aftermarket, permanently
WHD31P
located, manufactured home (USA only) or mobile home, where not
PROPANE MODEL
prohibited by local codes. See owner's manual for details. This
0-4500ft
16,000BTU/hr
63.7%
«Cet appareil doit être utilisé uniquement avec les types de gaz
indiqués sur la plaque signalétique et peut être installé dans une
maison préfabriquée (É.-U. seulement) ou mobile installée à demeure si
les règlements locaux le permettent. Voir la notice de l'utilisateur pour
plus de renseignements. Une trousse de conversion est fournie avec
Do not operate the fireplace with the glass removed,
cracked or broken. Replacement of the glass should be
CETTE UNITÉ.
AVERTISSEMENT:
Ne pas utiliser l'appareil si le panneau frontal en verre
LE FABRICANT.
n'est pas en place, est craqué ou brisé. Confiez le
remplacement du panneau à un technicien agrée.
AIR.
APPAREIL DE CHAUFFAGE
Improper installation, adjustment, alteration, service or maintenance
can cause property damage, personal injury or loss of life. Refer to
owner's manual. Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
L'ÉVACUATION PRÉCISE.
Un installation ou une modification inappropriée du réglage, du service
COMBUSTIBLES:
PLANCHER
0"
ou de l'entretien pourraient être la cause de dommages à la propriété de
EVENT SUPÉRIEUR
2"
1
"
L'installation et le service doivent être executés par un
installateur qualifié pour le gaz, une entreprise de service ou le
W385-1968 / A
PAGE 1 OF 2
general information
D'INFORMATION ET D'INSTALLATION.
CAUTION:
other flammable vapors away.
doivent être tenus éloignes de l'appareil.
appliance is supplied with a conversion kit."
cet appareil.»
CAUTION:
done by a licensed or qualified person.
WARNING:
ATTENTION:
blessures corporelles ou même la mort.
Consultez le manuel du propriétaire d'information.
fournisseur de gaz seulement.
PAGE 2 OF 2
DWG#: W385-1968
DATE: 06.11.14
20.1
W415-1338 / B / 09.25.18
EN
7