GB
Safety notes
• Installation is only possible in frost-free rooms.
• The switched-mode power supply is only suitable for
indoor use.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.
Operating conditions
®
Bluetooth
version 4.0.
The current version of the app required for using the system
must be installed on the control unit in advance.
The required App is available for free in the iTunes Store
(requires an Apple account) and the Google Play store
(requires a Google account), see fold-out page I.
For operation under adverse environments, in buildings /
rooms with reinforced concrete walls, steel and iron frame, or
near of obstructions (eg furniture) of metal, the Bluetooth
reception can be disturbed and interrupted.
Type of obstructions
Interference or shielding
potential
Wood, Synthetic
Low
material
Water, Bricks, Marble
Medium
Plaster, concrete,
High
glass, solid wood
Metal
Very high
The transceiver operates in the ISM-frequency range
(2.4GHz). The installation in the vicinity of equipment with the
same channel occupancy should be avoided.
In cases of malfunktions, turn off the source of interference
shortly.
Technical data
37 324, 37 337:
• Voltage supply:
6V lithium battery type CR-P2
37 321, 37 336, 37 503:
• Voltage supply:
100-240 V AC 50-60 Hz/6.75 V DC
• Power consumption
®
Bluetooth
:
• Power consumption:
• Output:
®
• Bluetooth
- version:
® -
• Bluetooth
Transmission distance:
(depending on the environments)
3
• Wait time after flushing
• Minimum delay (2 – 10 s, adjustable)
• Detection zone according to Kodak Gray Card,
grey side, 8x10", landscape:
• Type of protection
- Fitting
- Transformer
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Installation
Operation,
see technical product information, 99.0409.xxx /
99.0438.xxx.
Activating setting mode
Disconnect the power supply to the electronics and reconnect
after 10 s.
The indicator lamp in the sensor system illuminates in setting
mode when the detection zone of the fitting is reached by an
approaching user.
Setting mode is automatically terminated after 3 minutes.
Maintenance
• Shut off water supply
• Switch off voltage supply
• Inspect and clean all components and replace if
necessary.
Batteries which are almost discharged are displayed
by a flashing indicator lamp in the sensor system.
4 W
Replacement parts
•see fold-out page I (* = special accessories)
1 W
®
Bluetooth
- Class 2
2.1 + EDR
about 10m
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
, see fold-out page II.
, see fold-out page III.
5 s
7 s
75 cm
IP 59K
IP 55
A
2
2500 V
100 °C