Technical Data; Scope Of Delivery; Accessories - Wilo Star-Z Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 41

5.2 Technical data

Connection voltage
Mains frequency
Protection class IP
Motor speed
Water temperature at
max. ambient temperature +40 °C
Max. ambient temperature
Max. operating pressure
Minimum inlet pressure
at +40 °C/+65 °C
Port-to-port length
Variable speed control
1)
The values apply up to 300 m above sea level; addition for higher locations:
0.01 bar/100 m increase in altitude. To prevent cavitation noises, be sure
to maintain the minimum inlet pressure at the suction port of the pump.
2)
For Star-ZD double pumps, a switchgear is required in addition for time-dependent
main/standby or parallel/peak-load operation.
5.3

Scope of delivery

• Complete circulation pump
• 2 flat gaskets
• Installation and operating instructions
5.4

Accessories

Accessories must be ordered separately:
• Thermal insulation shell (for single pumps only)
• Screwed connections
• S1R-h plug-in module, only for blocking-current proof
1~types, not for Star-Z 25/6.
See catalogue for a detailed list
Installation and operating instructions Wilo-Star-Z/-ZD
1)
2)
1 ~ 230 V ±10%
3 ~ 400 V ±10%
50 Hz
See rating plate
See rating plate
+2 °C to +65 °C
+40 °C
10 bar (1000 kPa)
0.05 bar/0.2 bar
(5 kPa/20 kPa)
140 mm/180 mm
3 stages
English
25

Publicité

Table des Matières
loading

Table des Matières