RBM84 connection <----> REM (single segments)
NOT INCLUDED
Cable
recommended type:
unshielded
multipair cable
(CAT 5 - U/UTP - AWG24)
see Annex A
from Rbm84 to the last Rem/Turnstile,
maximum distance must be 1000 m
RBM84 -
Connecting to A segment:
RBM84 is at the end of the cable path
Hardware and connections
RBM 84
Each Rem is identifi ed by Rbm84 through
a progressive sequential numbering (1 to
60) regardless of the position along the path
of the connection cable; such number (also
called address) must be set to the appro-
priate dip selector in the base Rem card.
In the event of communication problems be-
tween the Rem and the RBM84 card, position
Dip4 to ON on the last Rem connected.
REM
to successive Rem or Turnstile
(
INPUT OR OUTPUT CAN BE CONNECTED TO TERMINAL BLOCK
,
up to 60 units