What RBM84 can do
The following features are off ered for all these applications and for any system that includes access and/or exit points that require
authorisation/control/recording/monitoring:
For the system as a whole
-
Confi guration - within the system - of diff erent control devices, even for the same automation: a keyboard selector, transmitter
or transponder cards (magnetic or swipe), home control systems (Wave).
-
Automation enabling/disabling.
-
Digital input enabling/disabling.
-
Defi nition of 30 homogeneous groups of users for collective authorisation/denial.
-
Setting of 8 "vacant/occupied" control traffi c lights, with maximum number of spots and availability.
-
Selection of relay operating mode, bistable / monostable (with setting of monostable closing time).
-
Selection of contact type NO/NC, for all digital inputs.
-
Settings for 8 diff erent time brackets of the day.
-
Enabling/disabling of time brackets.
-
Programming of hourly costs for time brackets and whole day.
-
Set of 4 discount levels.
-
Programming complementary parking time limit.
-
Setting the timed AntiPassBack duration.
-
Programmed access opening and closing.
-
Defi nition of "blocked days": partial or total system lock-up
-
System lock-up/release.
-
Storage/recording of 5500 diff erent users with personal data and code of the control device assigned.
-
User list print function.
-
User operations per set time interval display or print function.
For each user
-
Association to a homogeneous group.
-
Enable/disable: edits or deletes user permanently
-
Defi nition of type of access: normal, time or amount prepaid, subscription (in days).
-
Antipassback type selection: normal or timed.
-
Setting of hourly costs for customised credits.
-
Allocation of discounts and complementary parking.
-
Allocation of time brackets on a daily basis.
-
Monitoring the status of the user: if recorded, last entrance and last exit, total stay, total accesses, remaining credit.
-
User confi guration print function.
-
User operations per set time interval display or print function.
All these functions can be activated/blocked/changed at any time through the software, and all drives connected to RBM84 and REM
can be locked/unlocked using the safety push buttons connected to digital inputs.
Technical data for individual components
RBM84
Power supply
120/230V
Maximum power
18W
Current draw when idle
40mA
Protection rating
IP54
Working
-20 / 55C°
temperature
RBM84 -
Hardware and connections
REM
PC30
120/230V
15V AC
8W
2.7W
34 mA AC
180mA AC
IP54
IP20
-20 / 55C°
-20 / 55C°
WA01
TSP00
S5000
120-230V
15V DC
12/24V
2.3W
0.45
1W
10mA AC
30mA DC
43mA AC
IP40
IP54
IP54
-20 / 55C°
-20 / 55C°
-20 / 55C°
S6000
S7000
PST001
-
10VDC
230V AC
-
0.05W
55W
-
3.2mA
130mA
IP54
IP54
IP44
-20 / 55C°
-20 / 55C°
-20 / 55C°
5