4.7.2 INSTALLING NATURAL VENT

Follow the instructions of the natural vent manufacturer for chim-
ney installation.
Remove and discard the two combustion air cover plates
A.
and gaskets located on the rear panel of the appliance.
Replace the four screws per side to secure the rear
B.
panel to the appliance.
Remove the spill switch bracket from the rear of the
C.
adapter.
Gently pull the two wire terminals (located inside the 7"
D.
fl ue collar at the top of the appliance) out approximately
8".
Bring the wires through the lower hole in the adapter and
E.
out the spill switch opening. To pass the wires through the
hole more easily, temporarily tape the two terminals together.
With the spill switch opening aligned to the back of the appli-
F.
ance, push the crimped edge of the adapter in to the appli-
ance fl ue collar.
Connect the wire terminals to the spill switch and re-secure
G.
the bracket.
Secure the terminal block into place as shown with the screw
H.
supplied.
Unscrew the wire access cover plate from the rear right hand
I.
side below the fi rebox. Remove and discard the gasket. Re-
move the knockout from the cover plate and insert the protec-
tive bushing. Pull both spill switch wires through the bushing
taking up any slack. Replace the cover plate. Connect one wire end to the terminal block and the other
end to terminal 1 of the gas valve. Connect the two wires running down the left side of the appliance
from the on/off switch to the remaining tab on the terminal block and to terminal 3 on the gas valve.
For aesthetics, the adapter has
been designed to accept a stan-
dard matte black 7" stove pipe and
the decorative band (standard with
the GS-150KT). Both are available
from your local authorized dealer /
distributor.

4.7.3 NATURAL VENT

Attach the Natural Vent label, shown, in the control area of the appliance.
ATTACH THIS LABEL IN THE CONTROL AREA OF THE APPLIANCE.
THIS APPLIANCE HAS BEEN CONVERTED TO A NATURAL VENT
MODEL.
ATTACHEZ CET ETIQUETTE DANS LA REGION DE CONTROLE DUE FOYER.
CET APPAREIL A ÉTÉ CONVERTI À UN MODÈLE À TIRAGE
NATUREL.
COMBUSTION AIR COVER
PLATES AND GASKET
SPILL
SWITCH
TERMINAL BLOCK
A / W385-0160
27
ADAPTER
WIRE ACCESS
COVER PLATE