2.4
RATING PLATE INFORMATION
INSTALLER: It is your responsibil-
ity to check off the appropriate
box on the rating plate according
to the model, venting and gas
type of the appliance.
For rating plate location, see "IN-
STALLATION OVERVIEW" section.
This illustration is for reference only.
Refer to the rating plate on the appli-
ance for accurate information.
W415-0153 / E / 05.28.12
CERTIFIED UNDER: CSA 2.33-2009, ANSI Z21.88-2009 VENTED GAS FIREPLACE HEATERS. / HOMOLOGUE
SELON LES NORMES: CSA 2.33-2009 , ANSI Z21.88-2009 FOYER DE CHAUFFAGE AU GAZ AVEC
CDVS280-N
9700539 (WSL)
4001657 (NGZ)
4001658 (NAC)
4001659 (WUSA)
0-4500FT(0-1370m)
30,000 BTU/h
18,000 BTU/h
REDUCED INPUT / ALIMENTATION REDUITE
22,500 BTU/h
OUTPUT(MODEL CDVS280/GDS28) RENDEMENT
24,000 BTU/h
OUTPUT(MODEL CS280/GS28) RENDEMENT
MANIFOLD PRESSURE:
3.5" W.C. (NG) / 10" W.C.(LP)
PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU(GN)
10" D'UNE COLONNE D'EAU (PG)
MIN SUPPLY PRESSURE:
4.5" W.C.(NG) / 11" W.C. (LP)
PRESSION D'ALIMENTATION MIN: 4.5" D'UNE COLONNE D'EAU (GN)
11" D'UNE COLONNE D'EAU (PG)
MAX. SUPPLY PRESSURE:
7" W.C. (NG) / 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 7" D'UNE COLONNE D'EAU (GN)
13" D'UNE COLONNE D'EAU (PG)
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES
SEULEMENT AVEC CETTE UNITE.
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE,
WHICH WILL COME IN CONTACT WITH THE FLAMES, OTHER THAN
THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL
AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC
LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI
AVEC CET APPAREIL PAR LE FABRICANT.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL /
DEGAGEMENTS MINIMAUX DES MATERIAUX
UX
UX
COMBUSTIBLES:
A
7"
D
17½"
B
2"
E
6¼"
C
1"
F
9½"
20" TO CEILING FROM STOVE TOP
E T
E TOP
20" ENTRE LE DESSUS DU FOYER ET LE PLAFOND
U FOYER ET LE PLAFOND
FOYER ET LE PLAFOND
ELECTRICAL RATING / CLASS.: 115V 1.5AMP 60HZ
CLASS.:
LASS.:
115V 1.5AMP 60HZ
115V 1.5AMP 60HZ
MODEL CS280/GS28
EL CS280/GS28
EL CS280/GS28
APPROVED F
APPROVED FOR
PPROVE
BEDROOM, & BEDSITTING ROOM INSTALLATION.
ROOM, & BEDSITTING ROOM INS
OOM, & BEDSITTING ROOM INS
HOMOLOGUE POUR INSTALLATION DANS UNE
MOLOGUE POUR INSTALLATION
OLOGUE POUR INSTALLATION
CHAMBRE A COUCHER, & UN STUDIO.
MBRE A COUCHER, & UN ST
BRE A COUCHER, & UN
STEADY STATE EFFICIENCY (NG): 80% FAN OFF / 82% FAN ON
Y STATE EFFICIENCY (NG):
STATE EFFICIENCY (NG
STEADY STATE EFFICIENCY (LP): 80% FAN OFF / 83% FAN ON
TATE EFFICIENCY (LP
EFFICIENCY (LP
EFFICACITE CONSTANTE (GN):
CONSTANTE
CONSTANTE
80% VENT. ARRETE
82% VENT. FONCTIONNE
EFFICACITE CONSTANTE (GP): 80% VENTILATEUR ARRETE
TAN
83% VENTILATEUR FONCTIONNE
STEADY STATE EFFICIENCY APPLIES TO CANADA ONLY /
L'EFFICACITE CONSTANTE S'APPLIQUENT SEULEMENT AU CANADA.
AFUE (NG/LP) (GN/GP): 66% / 68%
THIS APPLIANCE MUST BE INSTALLED USING AN ADAPTER
KIT GS-150KT. CET APPAREIL DOIT ETRE INSTALLE EN
UTILISANT UN ENSEMBLE ADAPTATEUR GS-150KT.
NOT FOR USE WITH SOLID FUEL
UN COMBUSTIBLE SOLIDE NE DOIT
PAS ETRE UTILISE AVEC CET APPAREIL
GDS28-N
DIRECT VENT MODEL
GS28-N
'B' VENT MODEL
CS280-N
ALTITUDE / ELEVATION
0-4500FT (0-1370m)
*INPUT / ALIMENTATION*
CDVS280/GDS28
APPROVED FOR BEDROOM,
BATHROOM & BEDSITTING ROOM INSTALLATION. SUITABLE
FOR MOBILE HOME INSTALLATION IF INSTALLED IN
LATION IF INSTALLED IN
ATION IF INSTALLED
ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA
E CURRENT STANDARD CAN/CSA
RRENT STANDARD CAN/CSA
Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN
EQUIPPED MOBILE HOMES, IN
CANADA OR IN THE UNITED STATES THE MANUFACTURED
UNITED STATES THE MANUFACTUR
HOME CONTRUCTION AND SAFETY STANDARD, TITLE 24
CTION AND SAFETY STANDARD, TIT
TION AND SAFETY STANDARD, TIT
CFR, PART 3280. WHEN THIS US STANDARD IS NOT
80. WHEN THIS US STANDARD IS NO
80. WHEN THIS US STANDARD IS NO
APPLICABLE USE THE STANDARD FOR FIRE SAFETY
E USE THE STANDARD FOR FIRE SA
USE THE STANDARD FOR FIRE S
CRITERIA FOR MANUFACTURED HOME INSTALLATIONS,
A FOR MANUFACTURED HOME INST
MANUFACTURED HOME INS
SITES AND COMMUNITIES, ANSI / NFPA 501A.
S AND COMMUNITIES, ANSI / NFPA 50
AND COMMUNITIES, ANSI / NFPA 5
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A
MOLOGUE POUR INSTALLATION DAN
MOLOGUE POUR INSTALLATION DAN
COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE
COUCHER, UNE SALLE DE BAIN ET U
COUCHER, UNE SALLE DE BAIN ET U
POUR INSTALLATION DANS UNE M
POUR INSTALLATION DANS UNE M
POUR INSTALLATION DANS UNE MAISON MOBILE SI SON
INSTALLATION CONFORME AUX EXIGENCES DE LA NORME
INSTALLATION CONFORME AUX
INSTALLATION CO
CAN/CSA Z240MH SERIE DE
CAN/CSA Z240M
CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU
AVEC
AVEC
GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA
GAZ, EN VIGUEUR AU CAN
Z, EN VIGUEU
RNI
RNI
NORME DE SECUR
NORME DE SECURITE
NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS
MANUFACTUREES, T
MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE
MANUFACTUREES,
ATERIAL /
RIAL /
CAS OU CETTE N
CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE
CAS OU CETTE N
APPLIQUE
APPLIQUEE, SE
APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE
DE MESURE
DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES
E MESUR
INSTALLA
INSTALLA
INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES
SITES
SITES ET LES COMMUNAUTES, ANSI/NFPA 501A .
SITE
STE
STE
STEADY STATE EFFICIENCY (NG): 75% FAN OFF / 78% FAN ON
S
S
STEADY STATE EFFICIENCY (LP): 75% FAN OFF / 79% FAN ON
EFFICACITE CONSTANTE (GN):
EFFICACITE CONSTANTE (GP): 75% VENTILATEUR ARRETE
79% VENTILATEUR FONCTIONNE
STEADY STATE EFFICIENCY APPLIES TO CANADA ONLY /
L'EFFICACITE CONSTANTE S'APPLIQUENT SEULEMENT AU CANADA.
AFUE (NG/LP) (GN/GP): 64% / 65%
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE
25 INCHES AND 20 FEET RESPECTIVELY. LES LONGUEURS
HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES
ET 20 PIEDS RESPECTIVEMENT.
THE APPLIANCE MUST BE VENTED USING THE
APPROPRIATE NAPOLEON VENT KITS. SEE OWNERS
INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER
REINSTALLATION AND RESEALING IS NECESSARY AFTER
SERVICING THE VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT
L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON.
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE
POUR L'EVACUATION PRECISE. IL EST IMPORTANT DE BIEN
REINSTALLER ET RESCELLER L'EVENT APRES AVOIR
ASSURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
SERIAL NUMBER
GDS28
NO. DE SERIE
EVACUATION.
GDS28-P
CDVS280-P
GS28-P
CS280-P
26,000 BTU/h
15,000 BTU/h
19,500 BTU/h
BTU
BTU
20,800 BTU/h
00 BTU/h
00 BTU/h
D FOR BEDROOM,
FOR BEDROOM
OM INSTALLATION. S
OM INSTALLATION. SUI
MOBILE HOMES, IN
S THE MANUFACTU
75% VENT. ARRETE
78% VENT. FONCTIONNE
F
W385-0165 / F