Napoleon GDS28N Mode D'emploi page 32

Table des Matières

Publicité

32
6.0 OPERATION
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT
TAMPERING WITH THE SPILL SWITCH CAN RESULT IN CARBON MONOXIDE (CO) POISONING AND
MODEL GS28 ONLY: SPILL SWITCH
This is a thermally activated switch, attached to the back of the chimney adaptor, which senses the change in
temperature and shuts down the gas valve in the event of a blocked or disconnected vent. It acts as a safety
shut-off to prevent a build up of carbon monoxide or an explosion of unburned gases during start up. If the
fl ue is blocked or has no "draw", the spill switch will automatically shut off the supply of gas within about 5-10
minutes.
MODEL GS28 ONLY: VENTING ACTION CHECK
A CHECK FOR CORRECT VENTING ACTION MUST BE MADE BEFORE THE INSTALLED APPLIANCE IS
LEFT WITH THE CUSTOMER. Test in the following manner:
Close all doors and windows in the room / start exhaust fans in the home / turn appliance blower off (if
A.
equipped).
Set controls to "high" and light the appliance.
B.
Wait 5 minutes. Light a match and extend it 1" into the hole located above the spill switch bracket on
C.
the adaptor.
Venting action is satisfactory if the fl ame stays lit. Venting action is unsatisfactory if the fl ame
D.
extinguishes.
If venting action is unsatisfactory, turn the appliance off, wait 10 minutes and try again. If the match
E.
does not stay lit, turn the appliance off and check for vent blockage or restriction. If necessary, consult
with a qualifi ed inspector.
W415-0153 / E / 05.28.12
CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
WITH THE GLASS DOOR OPENED OR REMOVED.
POSSIBLE DEATH (GS28 ONLY).
WARNING
!

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gs28nGds28pGs28pGds28-1nsbBci2707737

Table des Matières