EXTENSION CORDS

Asphyxiation hazard. Extension cords running directly
into the home increase the risk of carbon monoxide
poisoning through any openings. If an extension cord
running directly into your home is used to power indoor
items, there is a risk of carbon monoxide poisoning to
people inside the home. Always use battery-powered
carbon monoxide detector (s) that meet current UL 2034
safety standards when running the generator. Regularly
check the detector (s) battery.
Asphyxiation hazard. When operating the generator with
extension cords, make sure the generator is located in
an open, outdoor area, far away from occupied spaces
with exhaust pointed away.
Fire and electrocution hazard. Never use worn or
damaged extension cords. Damaged or overloaded
extension cords could overheat, arc, and burn resulting
in death or serious injury.
Before connecting an AC appliance or power cord to the
generator:
• Use grounded 3-prong extension cords, tools, and
appliances, or double-insulated tools and appliances.
• Make sure the tool or appliance is in good working
order. Faulty appliances or power cords can create a
potential for electric shock.
• Make sure the electrical rating of the tool or appliance
does not exceed the rated power of the generator or the
receptacle being used.
OPERATION
EXTENSION CORD SIZING
Only use grounded 3-prong extension cords marked for
outdoor use that are rated for the electrical load.

PARALLEL OPERATION

Fire and electrocution hazard. Never connect or
disconnect the parallel cord leads when a generator is
running.
Connecting the iGen4500DF to a generator that is not
compatible can cause a low voltage output that can
damage tools and appliances powered by the generator.
Parallel operation gives you the ability to link the
iGen4500DF to a compatible Westinghouse Inverter
Generator for combined running and peak power output.
A Westinghouse parallel cord (purchased separately) is
required for parallel operation. This cord can be purchased
from an authorized Westinghouse Generator dealer.
Note: Do not use ECO MODE when in parallel operation
with another Westinghouse generator.
Parallel cord (50A/6000 Watts): Part# 507PC
Note: Compatible Westinghouse generators without
parallel ports can be operated in parallel with the
receptacle-mounted parallel cable, Part# 260041.
1. On both generators, make sure the battery switch and
the ECO MODE switch are in the OFF position.
2. Connect the black and red parallel cable leads to the
black parallel ports on each corresponding generator
control panel as shown below. Connect the black lead
to the left port, the red lead to the right port.
Westinghouse Outdoor Power Equipment, LLC | 19