Function test
After connecting to the power supply, the warm-up time is
60 sec. The internal LED then flashes and the connected users
are switched on. The motion detector is ready for operation,
if LED and user are switched off. The function test serves to
test the motion sensor for proper detection function in the
desired installation location.
In order to perform the function test, set the arrow
"test" position.
To do this, make the following settings:
to AUTO.
Set the sliding switch
6
Turn the METER adjustment screw
Turn the TIME adjustment screw
The twilight detection is deactivated.
Correctly install the motion sensor and connect it to the
mains voltage
.
4
5
from outside of the probable detec-
Begin the function test
11
tion range and pass through the detection range transversally
until the motion sensor switches.
The LED
and the connected consumer switch for 2 seconds.
10
Adjust the "METER" adjustment screw
tection range is set.
Repeat the function test
achieved.
8
to the "+" position.
9
to the "test" position.
8
until the desired de-
9
until a satisfactory result is
11
11
to the
Start
Manual ON (button activation)
For this, connect one or more buttons to the normally open
contact on the T
button (normally open contact) and switch the motion sen-
sor ON (regardless of the set twilight threshold). The motion
detector switches off again in accordance with the set duty
cycle.
Finish
terminal of the motion sensor. Press the