TECHNICAL DATA
Rated input ..............................................................................
Output ......................................................................................
No-load speed, 1st gear/2nd gear ...........................................
Speed under load max., 1st gear/2nd gear .............................
Percussion rate........................................................................
Rate of percussion under load max. ........................................
Static jamming moment*, 1st gear/2nd gear ...........................
Drilling capacity in concrete .....................................................
Drilling capacity in brick and tile ..............................................
Drilling capacity in steel ...........................................................
Drilling capacity in Aluminium ..................................................
Drilling capacity in wood ..........................................................
Drill opening range ..................................................................
Drive shank..............................................................................
Chuck neck diameter ...............................................................
Weight without cable ...............................................................
Noise information
Measured values determined according to EN 60 745.
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K = 3 dB(A)) .......................................
Sound power level (K = 3 dB(A)) ............................................
Wear ear protectors!
Vibration information
Total vibration values (vector sum in the three axes)
determined according to EN 60745.
Vibration emission value a
:
h
Drilling into metal .....................................................................
Uncertainty K ...........................................................................
Percussion drilling into concrete ..............................................
Uncertainty K ...........................................................................
Measured values determined according to EN 60 745.
The data stated above apply for models with 230 - 240 V. In case of deviating mains voltage, the data stated on the rating
plate are applicable.
* Measured according to AEG norm N 877318
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given
in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained, the vibration emission may differ. This may significantly increase
the exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may significantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
WARNING! Read all safety warnings and all
instructions, including those given in the accompanying
brochure. Failure to follow the warnings and instructions
may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Wear ear protectors. Exposure to noise can cause hearing
loss.
Use auxiliary handles supplied with the tool. Loss of
control can cause personal injury.
Hold power tool by insulated gripping surfaces, when
performing an operation where the cutting accessory
may contact hidden wiring or its own cord. Contact with
a „live" wire will also make exposed metal parts of the power
tool „live" and shock the operator.
Appliances used at many different locations including open
air should be connected via a residual current device of
30 mA or less.
Always wear goggles when using the machine. It is
recommended to wear gloves, sturdy non slipping shoes
and apron.
20
ENGLISH
..................................750 W
..................................375 W
................ 0-1200/0-3400 min
-1
.........................750/2200 min
-1
..............................54400 min
-1
..............................36000 min
-1
...............................58/30 Nm
....................................20 mm
....................................22 mm
....................................13 mm
....................................16 mm
....................................40 mm
............................. 1,5-13 mm
............................1/2"x20
....................................43 mm
...................................2,6 kg
....................................98 dB (A)
..................................109 dB (A)
...................................4,5 m/s
2
...................................1,5 m/s
2
....................................32 m/s
2
...................................6,4 m/s
2
Sawdust and splinters must not be removed while the
machine is running.
Always disconnect the plug from the socket before carrying
out any work on the machine.
Only plug-in when machine is switched off.
Keep mains lead clear from working range of the machine.
Always lead the cable away behind you.
When working in 1st gear always use the bow-type handle
and/or the auxialiarhandle. In case the machine is operated
with the bow-type handle, the lower area of the motor
housing might be used as auxiliary handle.
Do not use diamond core drills on hammer mode.
When working in walls ceiling, or floor, take care to avoid
electric cables and gas or waterpipes.
The dust produced when using this tool may be harmful to
health. Do not inhale the dust. Wear a suitable dust
protection mask.
SPECIFIED CONDITIONS OF USE
The electronic drill/screwdriver can be universally used for
drilling, percussion drilling, screwdriving and cutting screw
threads.
Do not use this product in any other way as stated for
normal use.
MAINS CONNECTION
Connect only to single-phase a.c. current and only to the
system voltage indicated on the rating plate. It is also
possible to connect to sockets without an earthing contact
as the design conforms to safety class II.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is
in conformity with the following standards or standardized
documents. EN 60745, EN 55014-1, EN 55014-2,
EN 61000-3-2, EN 61000-3-3, in accordance with the
regulations 98/37/EC, 2004/108/EC
Rainer Kumpf
Winnenden, 2009-11-04
Manager Product Development
MAINTENANCE
The ventilation slots of the machine must be kept clear at all
times.
If the machine is mainly used for percussion drilling,
regularly remove collected dust from the chuck. To remove
the dust hold the machine with the chuck facing down
vertically, and completely open and close the chuck. The
collected dust will fall from the chuck. It is recommended to
regularly use cleaner for the clamping jaws and the
clamping jaw borings.
Use only AEG accessories and spare parts. Should
components need to be exchanged which have not been
described, please contact one of our AEG service agents
(see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.
Please state the ten-digit No. as well as the machine type
printed on the label and order the drawing at your local
service agents or directly at: AEG Elektrowerkzeuge,
Max-Eyth-Straße 10, D-71364 Winnenden, Germany.
SYMBOLS
Please read the instructions
carefully before starting the
machine.
Always disconnect the plug from the socket
before carrying out any work on the
machine.
Accessory - Not included in standard
equipment, available as an accessory.
Do not dispose of electric tools together
with household waste material! In
observance of European Directive 2002/96/
EC on waste electrical and electronic
equipment and its implementation in
accordance with national law, electric tools
that have reached the end of their life
must be collected separately and returned
to an environmentally compatible recycling
facility.
ENGLISH
21