Maintenance And Cleaning - Oase LUNAQUA 3 Halogen Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

- English -

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Before reaching into the water, disconnect all units located in the water from the mains.
• Disconnect the unit from the mains before performing any work on the unit.
• Secure the unit to prevent unintentional switching on.
• Ensure that no moisture can enter the unit.
Cleaning the unit
If necessary, clean the unit with clear water using a soft brush.
Replacing the bulb
• Only use original bulbs from OASE. (→ Technical data)
− The unit may be damaged by the use of spare parts from other manufacturers.
How to proceed:
1.
0.
F
1. Unscrew the threaded ring.
2. Remove the glass pane and O ring, check for damage and replace if necessary.
3. Remove the defective bulb from the housing.
4. Insert the new bulb.
5. Reassemble the unit in the reverse order.
− Ensure that the O ring is correctly positioned.
6. Reconnect to the power supply and check the function.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
6
22752-11-13_GA_LunAqua 3 Halogen6 6
12.11.2013 11:42:48