Safety Considerations; Technical Data - Dustcontrol DC 5800c 9.2 kW P Notice Originale

Masquer les pouces Voir aussi pour DC 5800c 9.2 kW P:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety Considerations

Read all instructions before attempting to operate this
machine and save these instructions.
Warning! When using electric machines, basic safety
precuations should always be followed to reduce
the risk of fi re, electric shock and personal injury,
including the following:
1.
Work area environment
Don´t expose the machine for rain. Don´t use it in damp
or wet locations or in presence of fl ammable liquids or
gases.
2. Overload
Never let the machine operate fully throttled. Always
follow the regulations pertinent to the material you are
working with ie asbestos. Don´t use the machine for pur-
poses that it isn´t intended for.
3.
Body injuries
Never let the suction come in contact with parts of the
body. Th e strong suction eff ect can hurt the blood-vessels
in the skin. Do not repair the electric components your-
self, get somebody qualifi ed. Faults may cause injury. See
also below under warnings.
4. Don´t abuse cord
Never pull the machine by cord. Keep cord from heat and
sharp edges. Check the electric cable regularly if damage.

TECHNICAL DATA

HxWxL
Weight
Inlet
Collecting sack 50 l
Hose length (φ 50)
Flow, max
Neg. pressure, max
Power consumption
Fine fi lter polyester, area
Degree of separation
(DIN 24184/3)
Filter area, microfi lter
Degree of separation,
microfi lter (DOP)
Sound level */
2010-02-15
5.
Important measure
With cleaning and maintenance on the machine, the
power cable should be disconnected from the supply.
6. Maintain the machine with care
Keep machine clean and check that the hose is
entired and that all gaskets are tight. Follow instructions.
Keep handles dry and free from oil and grease.
7.
Checking of damage
Before futher use of the machine it should be carefully
checked that the machine is un damaged. If there are any
damaged parts these should be repaired by of a Dustcon-
trol authorized service center.
8. Warning
Use only accessories and replacable parts which are avai-
lable in Dustcontrol catalogue. When using faulty parts
or pirate parts (especially fi lter) the machine could leak
out unhealthy dust which can cause personal injuries.
Vacuum producer capacity
1800x760x1150 mm
ca 210 kg
φ 108 mm
kPa
40
700 x 850 mm
5-50 m
800 m
3
/h
28 kPa
20
9.2 kW
8.4 m
2
99.9 %
5 m
2
200
> 99,97 %
*/ Sound level at 1.6 m height and 1 m distance accor-
< 75 dB(A)
ding to DIN 45635 Section 1 (4/84) in free space and at
maximum airfl ow.
DC 5800c 9,2 kW P - 8
9,2 kW P
400
600
800
1000
3
m
/h
Part No 9092

Publicité

Table des Matières
loading

Table des Matières