4.2.3 Automatic Sequential Mode Operation
When pressing the SEQ
through three operating modes:
1.- Simultaneous activation of all sources without modulation.
2.- Sequential activation of modulated sources.
3.- It deactivates all sources.
In sequential mode, at the optical output [9] will appear the 1310 nm signal. After
few seconds appears the 1490 nm signal, after the same time appears the 1550 nm
signal and then again the 1310 nm signal. This process is repeated cyclically.
These three signals have been codified independently, in order to allow a
simultaneous analysis through a proper optical meter (like the PROLITE-67 of
PROMAX). Then it is not necessary to select each time the wavelength you want to
measure.
During operation in sequential mode the signals are modulated.
When pressing the SEQ
normal mode, at which the three laser sources can be used independently.
Page 10
[5] key, the PROLITE-105 passes sequentially
[5] key at the sequential mode, the unit switches to
USER'S MANUAL. PROLITE-105
03/2011