Air volume:
Stage 0: ......................... Off
Stage 1: .............. 3.6 cf/min
Stage 2: ............ 10.6 cf/min
Stage 3: ............ 15.0 cf/min
Temperature
adjustment:
stepless in 9 stages
per adjusting wheel
(Toleranz +/- 40°F)
1 = ca. 120 °F
2 = ca. 250 °F
3 = ca. 420 °F
4 = ca. 530 °F
5 = ca. 650 °F
6 = ca. 780 °F
7 = ca. 920 °F
8 = ca. 1050 °F
9 = ca. 1120 °F
Thermal protection: thermal fuse
Weight:
30.7 oz (870 g)
HE 23-650
Rated mains voltage: 120 V
Rated mains frequency:50/60 Hz
Output:
1600 W
Air temperature:
Stage 1: ....................120 °F
Stage 2: .......... 120-1200 °F
Blower:
steplessly adjustable
Air volume:
Stage 1: .......3.6- 8.8 cf/min
Stage 2: ......3.6-15.0 cf/min
Programs:
1=480 °F /
2=660 °F /
3=860 °F /
4=1000 °F /
Temperature display:LCD in 10 °F steps
Thermal protection: thermal fuse
Weight:
34.2 oz (970 g)
Conversion °C to °F
100 °C
=
212 °F
200 °C
=
392 °F
300 °C
=
572 °F
400 °C
=
752 °F
500 °C
=
932 °F
600 °C
=
1112 °F
700 °C
=
1292 °F
Conversion °F to °C
100 °F
=
38 °C
200 °F
=
93 °C
300 °F
=
149 °C
.approx. 7.0 cf/min
.approx. 9.5 cf/min
approx. 12.0 cf/min
approx. 10.8 cf/min
400 °F
=
204 °C
500 °F
=
260 °C
600 °F
=
316 °C
700 °F
=
371 °C
800 °F
=
427 °C
900 °F
=
482 °C
1000 °F
=
538 °C
1100 °F
=
593 °C
1200 °F
=
649 °C
Changes due to technological progress reserved.
Machine in protection class II
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).
ENGLISH
ENG
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

He 20-600He 23-650He 23-650 control

Table des Matières