3.3 Battery change display
If an empty battery symbol appears in the display when
the instrument is switched on or if this symbol
appears during a measuring operation, it means that new
batteries must be inserted. However, it is still possible to
use the instrument briefly.
The battery status can also be viewed from the menu.
Main menu
Device identifications
>
3.4 Switching the instrument on/off
The instrument switches on automatically as soon as the
protective cap for the measuring needles is removed. The
protective cap is reattached to switch it off again.
3.5 Calibration control
Menu
>
Two holes are located at the upper edge of the housing.
The value 19% (+/- 1%) must be illustrated on the display
in order to ensure a correct calibration. In the event of a
deviation in the value the instrument must be returned to
the customer service department of STORCH GmbH for
recalibration.
4. Explanation of the menu options:
Main menu
4.1 Language
You can select the desired language under this menu opti-
Language
on
.
4.2 Switch off time
The switch-off time can be set anywhere from 0 minu-
tes (no automatic switch-off) to 255 minutes (automatic
switch-off after 255 minutes). It must be noted that only
the display is switched off at this time and that the bat-
teries' energy is still being used. In order to prevent using
any energy at all, the protective cap must be attached
Battery status
>
Calibration control
>
-key
Basic setting
>
over the measuring needles (see 2.3 Switching on and
off).
4.3 Temperature unit (only for optional accessories / tem-
perature senor) The temperature unit can be measured in
°Celsius or °Fahrenheit. The desired unit can be selected
under this menu option.
4.4 Auto-Hold
This instrument is set for continuous measurement. This
means that a measurement is conducted continually.
However, if the value of a measurement e.g. at a diffi-
,
cult to access area should only take place once and then
be illustrated continuously on the display, then the func-
tion Auto-Hold can be activated under this menu option.
The OK key must be actuated in this mode of operation
in order to conduct a measurement. If a green LED illu-
minates it confirms that the measured value is going to
be illustrated continuously on the display. If another mea-
surement is conducted and the OK key is actuated, the
last value will disappear automatically.
4.5 Start setting
The material type that is to be selected when the instru-
ment is switched on is specified under the menu option
Start setting
Universal
means that the instrument will always
be set to the material type 'universal' when it is switched
on.
Last setting
means that the instrument "notes" the
material type last used.
4.6 Display
Display as a bar chart
In addition to the display format in figures (factory set-
ting), the measured value can also be displayed in a bar
chart format. The bar chart display enables a quicker
evaluation of the measurement results.
Night operating mode
When conducting measurements in unfavourable ligh-
ting conditions it is possible to change the display from
night operation (factory setting) to day operation. The day
operation display mode uses approximately 5 times more
28
Display in figures
Day operating mode