Natural Gas Connection
NewAge recommends that only qualified professionals perform the required gas
fitting on this product.
!
To ensure satisfactory performance, the gas supply line must be sized to
accommodate the total BTU/h requirements of all the gas-fired equipment that will
be connected to that line.
In no case should pipe less than 3/4" inside diameter or 1" outside diameter ever be
used to connect this product.
WARNING
• Calculate the total BTU output of all equipment and refer to Gas Supply Line Runs for allowable run
distances for ¾ inch pipe. Failure to meet these minimum requirements may reduce performance of the grill
and any other appliances running on that supply line.
• Always keep supply line runs as short as possible.
• A gas shut-off valve must be installed in an easily accessible location by a qualified licensed gas fitter.
• The outdoor cooking gas appliance and its individual shut-off valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures in excess of 0.5 psi (3.5
kPa).
•The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing its
individual manual shut-off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psi (3.5 kPa).
• Keep threading compound off of the first two pipe threads to avoid having any small pieces of compound
break loose and clog a burner valve or orifice. Do not use threading compound on any flare fittings.
For built-in installations, it is recommended that any flexible pipe used be kept as short as possible.
For freestanding units using natural gas, NewAge strongly recommends using a quick disconnect kit.
This Quick Disconnect kit, is included with purchase.
NOTE:This product must be installed by a licensed plumber or gas fitter when installed within the State of
Massachusetts.
Natural Gas connections
disconnect
Flexible Gas
Grill Intake
Disconnect
Hose
Manifold
24
www.newageproducts.com
Quick
Main shut-off valve
Tee Fitting
Quick
Threaded
Threaded
nipple
nipple
Coupler
To side burner
Rigid Connection in a Built in Enclosure
!
WARNING
Natural Gas Line
(Supplied)
Venting
Venting
Gas supply line
from meter
The grill can be connected to the gas supply by means of a flexible hose
connector complying with the current standard for elastomeric composite
hose and couplings CAN/ CGA-8.1 or withThe Standard for thermoplastic
Hose and Hose couplings Standard for Propane or N atural Gas, CAN1-8,3,
listed hose assembly if the grill is to be be connected to a cylinder other
than a No. 600 connection.
Non-Combustible
Construction
Rigid Piping for
Natural Gas
Side Burner Hose
(Not Supplied)
(Additional)
(Supplied with DSB)
All Other Components
Are Not Supplied
Rigid Piping
for Propane
(Alternative)
(Not Supplied)
www.newageproducts.com
Grill Natural Gas
Flexible Tubing
(Supplied)
Grill Propane
Rigid Piping
Flexible Tubing
for Propane
(Not Supplied)
(Alternative to NG)
(Not Supplied)
25