Saber R50SB1517 Manuel D'utilisation Et D'entretien page 29

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting - LED Lights
Problem (Lights)
Possible Cause
LED lights do NOT
LED wires disconnected.
illuminate when light
switch is pressed ON,
but LED light switch
illuminates.
Faulty LED light(s).
LED lights do NOT
Transformer lead wires
illuminate when light
disconnected (if used).
switch is pressed ON,
AND LED light switch
does NOT illuminate.
Switch wire harness
disconnected.
LED lights DO
Bad LED light switch.
illuminate when light
switch is pressed ON,
but LED light switch
does NOT illuminate.
Check Procedure
Check to ensure that wires at
each LED spade terminal are
firmly connected and not loose
behind control panel.
If good connection at LED, and
other LED lights are
operational, then bad LED.
Check that transformer output
connector is engaged and
locked with no loose wires at
the connectors.
Check that the switch wire
harness is connected properly
to back of switch.
Switch wire harness is
attached and LED lights
illuminate.
Prevention/Solution
Reconnect wires at spade connectors on the LED.
If wires will not stay attached and are loose,
contact Saber for warranty replacement parts.
Contact Saber for a warranty replacement part.
Reconnect the transformer wire connectors. If
wires pull loose from the connectors, contact
Saber for warranty replacement parts.
Reconnect switch wire harness to switch ensuring
that harness locks to switch.
Contact Saber for a warranty replacement part.
29

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

R67sb1017R50sb0412R67sb0312

Table des Matières