Dear Customer,
Congratulations on buying your Phocos product! Please read the instructions carefully and thoroughly before using the
product. It comes with a number of outstanding features, such as:
•
Maximum Power Point Tracking technology, which increases the efficiency of your PV system
The CIS-N-MPPT 100/30 charge controller can optimally charge batteries from 60-cell PV panels that have
•
primarily been designed for grid connected systems. (One panel for 12V systems or two panels in series for 24V
systems)
•
Negative grounding
Dimming function
•
Case protection: IP68, in 1.5 m deep water 72 hours
•
Control unit (CIS-CU) to configure CIS-N-MPPT 100/30 charge controller, via infra-red data link available as
•
accessory (sold separately). CIS-CU required to modify the factory default settings.
External temperature sensor for temperature compensation of charging voltages
•
4 stage charging (main, boost, equalization, float) for flooded battery; 3 stage charging (main, boost, float) for
•
sealed and lithium (LFP) batteries
Automatic recognition of system voltage 12/24 V
•
Widely programmable
•
LFP (LiFePO4) lithium battery wake-up function
•
General Safety Information
This manual contains important installation, set up, and safety operating instructions.
Please read the instructions and warnings in this manual carefully before beginning any installation.
Please do not disassemble or attempt to repair Phocos products. Phocos charge controllers do not contain user
serviceable parts.
Please observe all instructions with regards to external fuses/breakers as indicated.
The information contained in this manual must be observed in its full extent. The manual contains information regarding
installation, set up, and operation.
Please read this manual carefully before using the product, and pay special attention to the safety recommendations in
it.
Maintenance and installation notes
When installing or working on the PV system, please disconnect the PV (solar) modules from the charge controller first,
to prevent any damages to the charge controller!
Please verify that all cable/wire connections are done properly and well insulated and that no water or humidity can
ingress that is to avoid any bad or loose connections that would result in excessive heating or further damage.
Please install a fuse or breaker near the battery before installing or adjusting the controller!
High voltage risks
Never touch any electrical conductors to avoid electrical shock.
Never work on live (energized) electrical equipment.
When working around a battery, do not allow tools to bridge the battery terminals, or short circuit any part of the battery.
Use only tools with insulated handles.
Operation of this device may produce a high voltage which could cause severe injuries or death in case of improper
installation or operation of the device.
PV modules can generate high DC voltages!
www.phocos.com