Setting procedure:
1. Put the [ 0/I ] switch to position [I].
2. Use the [ ] / [ ] keys to set the output voltage to about 25% of the maximum voltage.
3. Increase the output voltage in steps, until the correct bonding strength is reached.
4. Set the output voltage about 10 % higher to accommodate for process fluctuations.

6.2.2. With Remote Voltage Programming:

The output value can be set using an external analog voltage (see par. 8.3 and the appended
connector pinout). The supplied external voltage must be between: 0-10 VDC.
This voltage can be used to adjust the output voltage between 0 and 100% of the maximum
value.
Setting procedure:
1. Put the [0 / l] switch in the [l] position.
2. Supply an external voltage to set the output voltage to about 25% of the maximum voltage.
3. Increase the output voltage until the correct bonding strength is reached.
4. Set the output voltage about 10 % higher to accommodate for process fluctuations.

6.3. Display readings

The CM Medium display gives the actual output voltage.
Hint:
Note the required voltage. This information makes it easier to reset the system and
-
provides information on any wear on the points of the charging bar/electrode.
Switch off the system when it is not in use. This prevents unnecessary wear.
-

7. Functional check

The [OVERLOAD] LED will light up:
in case of spark-over
-
-
when the generator is overloaded (maximum current is reached). With an overload, the
output voltage is decreased until the maximum current is supplied.