Globe & Guard Assembly or Lamp Replacement Instructions (Continued)
CAUTION: ELECTRIC SHOCK HAZARD: DISCONNECT handlamp from power source and remove to a safe area
(beyond the hazardous operating environment) before inspection or repair work is attempted.
NOTE: When performing the following replacement steps, avoid letting any liquid enter the handle. Ensure that the inside
of the globe and handle are completely dry of ALL liquids before reassembling the handlamp.
1. Unplug the handlamp from power source and make sure to remove it to a safe area beyond the hazardous operating environment.
Then, use an Allen wrench (hex key) to loosen the set screw on the lower edge of the guard.
2. Insert the Guard Housing Jig into a bench vise and tighten the vise onto the jig.
Appleton • 1.800.621.1506 • www.appletonelec.com
FIGURE 4: LOOSEN THE EHLED'S SET SCREW
FIGURE 5: GUARD HOUSING jIG TIGHTENED INTO bENCH vISE
DOC00038A000 Rev. 00 02/13/20 MY6381 • Page 5 of 16