Short Description
Intended Use
The loop-powered isolator is used for transmitting 0(4) ... 20 mA standard signals
with galvanic isolation between input and output. The measurement signal is trans-
mitted at a ratio of 1:1. A separate power supply is not required. The loop-powered
isolator is not free from feedback. That means that an overload of the output load
disturbs the input circuit.
The loop-powered signal splitter provides two identical outputs from one input
signal. It is not free from feedback.
Protection against Polarity Reversal
When input or output polarity are reversed and the current is too high, a resettable
fuse (PTC) trips and breaks the circuit. When polarity reversal is corrected, the fuse
will recover and current will flow again (recovery time: approx. 1 minute).
Warranty
Defects occurring within 5 years from delivery date shall be remedied free of charge
at our plant (carriage and insurance paid by sender).
Product Range
Designation
ProLine P22401 P1
ProLine P22402 P1
ProLine P22412 P1
Disposal
Please observe the applicable local or national regulations concerning the
disposal of "waste electrical and electronic equipment".
Description
Loop-powered isolator for standard
signals, 1 channel
Loop-powered isolator for standard
signals, 2 channels
Loop-powered splitter for standard
signals
19
Order number
P22401P1
P22402P1
P22412P1