Technical Data - LaserLiner PowerCross-Laser 8 S Mode D'emploi

Masquer les pouces Voir aussi pour PowerCross-Laser 8 S:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
Checking the vertical line: Position the device about 5 m from a wall. Fix a
plumb bob with a line of 2.5 m length on the wall, making sure that the bob
can swing freely. Switch on the device and align the vertical laser to the plumb
line. The precision is within the specified tolerance if the deviation between the
laser line and the plumb line is not greater than ± 0.5 mm.
Checking the horizontal line:
Position the device about 5 m from a wall and
switch on the cross laser. Mark point B on the
wall. Turn the laser cross approx. 2.5 m to the
right and mark point C. Check whether the
horizontal line from point C is level with point B to within ± 0.5 mm.
Repeat the process by turning the laser to the left.
!
Regularly check the adjustment before use, after transport and after
extended periods of storage.

Technical data

Self-levelling range
Precision
Laser wavelength linelaser / plumb laser
Laser class / output power
Power supply
Battery operating time (all lasers on)
Battery recharging time
Weight (incl. rechargeable battery)
Dimensions (W x H x D)
Operating temperature
Storage temperature
Subject to technical alterations
PowerCross-Laser 8 S
B
± 1 mm / 10 m
635 nm / 650 nm
Lithium-ion rechargeable battery
approx. 8 h
approx. 6 h
1.6 kg
130 x 225 x 130 mm
0°C ... + 50°C
-10°C ... + 70°C
04/2016
2.5 m
C
21
GB

Publicité

Table des Matières
loading

Table des Matières