After use
CAUTION
• Do not pull the power cord to disconnect it from the wall outlet. Always hold it by the plug.
This can damage the metal core of the cord and may result in fire, short circuit or electric shock.
• Occasionally clean the prongs of the power plug with a dry cloth.
If dust settles between the prongs, the dust will collect moisture, and short circuit or fire may occur.
• If the instrument is not to be used for a long time, disconnect the power cord from the wall outlet.
Fire may result.
• Do not store the instrument in an area that is exposed to rain, water, or where toxic gas is present or any
liquids are stored.
• Maintain the surrounding temperature and humidity at the following ranges during transport and storage of
the instrument.
•
Environmental conditions
Temperature: -20 to 60°C (-4 to 140°F)
Humidity: 20 to 85% (non-condensing)
Transport handling: To prevent leakage, keep the right side up, and handle with care. Only stack up to the
specified number of units.
• When transporting the instrument, use the special packing materials to protect the instrument from shock
or impact.
Excessive vibration or impact to the instrument may cause malfunction.
Maintenance
WARNING
• Contact NIDEK or your authorized distributor for wheel replacement.
Wheel replacement by other than authorized service personnel may result in injury.
• In dressing mode, the wheels are rotating with the processing chamber cover open. Work with special
care during dressing.
• Wear protective glasses for wheel dressing.
Spray containing processing waste may cause eye damage.
• Be sure to check before use and after use. It is recommended to have regular maintenance checks every
two years.
As malfunction or injury may occur, do not replace any parts other than fuses, cooling fan filter, or stocking
filter. Do not attempt to repair or disassemble the instrument.
• Use only the specified fuses for replacement.
Use of any fuses other than those specified may result in fire.
•
Fuse rating
T 12 AL 250 V: AC 100 to 120 V regions
T 8 AL 250 V: AC 230 V regions
• Before fuse replacement, turn off the instrument and disconnect the power cord from the wall outlet.
Electric shock may occur.
• Hold the dressing stick with both hands. Hold the dressing stick with a minimum of 2 or 3 mm protruding
when dressing the wheel.
Failure to do so may cause injury by hand contact with the wheel as the dressing stick wears away.
• When the dressing stick is worn to the length of 4 cm, replace it with a new one.
It is hard to hold the shortened dressing stick resulting in finger injury or wheel damage.
6