TECHNICAL FEATURES
TYPE
Motor Power
Lifting Power
Voltage
Current
Torque
Speed
Working atmosphere temperature
Maintenance
Maximum travel
Thermal
Capacitor
Operator's weight
ACCESORIES PROVIDED WITH MOTOR
Supplement for pulley D.210/220 mm.
Supplement for shaft D.42/48 mm.
Electric wire 4 x 1 mm² - Lenght 4 m.
OPERATOR'S MOUNTING (Fig. 1 and 3)
Drill in the shutter's central shaft (Fig. 3), one hole Ø 10,5 mm. in order the operator doesn't turn, and another Ø 12,5 mm. for the electric
wire.
If possible, place the operator in the centre of the shutter's shaft in an easy position for opening the micro-switches lid to make the wire
and the regulation of the limit switches.
In case of electric brake, make another drill of Ø 10 mm. for the cable of the manual release.
Open the pulley unscreWINg the M8x25 screws (using an hexagonal wrench of 6 mm.)
Remove the plastic roller band without folding it and keep it in a clean place.
Separate the gear-motor's body removing the 4 screws with the 6mm. hexagonal wrench.
Couple the two parts of the gear-motor around the door's shaft and joint them screWINg the 4 screws on the gear-motor's support.
If the shaft is not Ø 60 mm. use the supplement of Ø 42/48 mm.
Tighten the M10x40 screw [Fig. 1 (A)] entering it into the Ø 10,5 mm. hole of the shutter's shaft.
Put again the plastic roller band in its place.
Apply again the pulley by coupling the two parts and tighten the screws.
Screw also the M10x40 [Fig. 1 (B)] pressing on the shaft till the gear-motor is blocked and tighten the nut. The operator should be fixed,
lined and the pulley must turn freely.
Make a hole Ø 12 mm. in the last canvas of the shutter at the same location of the hole and nut M10 of the pulley [Fig. 3 (1)]. (if the
shutter is waved or not regular, it is necessary to couple a flat metal piece of 1 meter to the pulley of the WIN.).
Travel the electric cable trough the shaft's hole de Ø 12,5 mm. (Fig. 3), avoiding any contact with the rotating parts and make the wires
(Fig. 2).
In case of motor with electric brake travel also the brake cable through the hole of Ø 10 mm. drilled in the shaft (Fig. 3), and mount the
manual release. For a proper release the flexible cable of the brake should not do any exaggerated curve. (Fig. 12).
ELECTRIC WIRE (Fig. 2)
To do connections remove first the protecting lid of the limit switches [Fig. 1 (J)]
Travel the electric cable through the stuffing box and do the wires.
It is very important the correct wiring of the common (N blue) and the ground.
SECURITY STANDARD: The connection wires should come from a differential switch.
In the type with brake the electric brake is yet wired.
In case of no brake it is compulsory a jumper between the two terminals [Fig. 2 (3)].
For fitting the electric brake, remove the jumper and connect the two wires of the reel [Fig. 2 (3)].
CHECKING THE OPERATION DIRECTION
Place the closing stop collar (C1) next to press the micro-switch (C) [Fig. 4].
Switch on current on the motor, if it stops at closing it's correct. If not switch off and change the position of the wires 3 and 4
(ROLLER,
P-10/P-23 o P-10/P-23E) (Fig. 6), or the wires that go to the motor (P-5/2 or open-close push-button)
(Fig. 2). It is very important the correct wiring of the common (N blue) .
REGULATION OF THE OPENING LIMIT-SWITCH (SEMI-AUTOMATIC) (Fig. 4)
Fix the shutter to the pulley with the M10x20 screw and the nut. (Fig. 5).
If necessary use the supplements Ø 210 or 220 mm.
Switch on and make the operator opens the shutter, stop when the door is open.
Close the door (electrically).
Move manually the opening stop collar (D1) 2 lines in the picture on the board. [Fig. 4] with the red lever pushed (E). Once set, release the lever.
Check the travel (adjust if necessary ).
INSTALLATION OF TWO MOTORS IN ONE SHUTTER (Fig. 6)
Mount the two operators WIN [Fig. 6 (M1 y M2)] one at any side of the drum, with the pulleys to the edges, in an easy position for
opening the micro-switches lid to make the wires and the regulation of the limit switches.
To mount the two operators in the drum follow the same instructions that for mounting one.
6
WIN22
WIN22P
400 W
140 Kg
180 Kg
230 V 50/60 Hz ±7%
1,8 A
135 Nm
175 Nm
10 rpm
GREASE THE DRIVING PULLEY ONCE A YEAR
7'
7,5 Kg
8,9 Kg
WIN Series
WIN24
600 W
180 Kg
2,8 A
185 Nm
8 rpm
-20°C / +85°C
6 mts
10'
25 µF
12,4 Kg
WIN24BM
1200 W
320 Kg
5,6 A
370 Nm
17,5 Kg