ALTF 1 surface contact sensors are electric contact thermo meters
and are used for measuring surface temperatures of solids, having at least one so-called
contact area that is brought into contact with the surface to be measured.
The surface contact temperature sensor THERMASGARD
and passive output determines the temperature of a medium flowing inside a pipe (e.g.
water temperature) via the surface temperature.
®
THERMASGARD
ALTF 1 is a tube contact resistance thermometer with strap and axial
feeler tube for temperature detection at piping and tubes (e.g. coldwater and hot-water),
or at heating sections for heating system control.

TECHNICAL DATA:

Measuring range: ....................... - 35 ...+105 °C PVC
Sensors ⁄ output: ........................ see table, passive
Connection type: ........................ 2-wire connection
Testing current: .......................... ca. 1 mA
Process connection: .................. endless strap and metal tightener
Protective tube: .......................... stainless steel, 1.4571, V4A,
Strap dimensions: ...................... Ø = 13 - 92 mm (¼ - 3"); length 300 mm
Connecting cable: ....................... PVC; 1,5 m, LiYY, 2 x 0,25 mm² or
Insulating resistance: ................ ≥ 100 MΩ, at 20 °C (500 V DC)
Humidity: ...................................... < 95 % r. H.
Protection class: ........................ III (according to EN 60 730)
Protection type:.......................... IP 65 (according to EN 60 529),
Type ⁄ WG1
ALTF 1 Pt100
ALTF 1 Pt1000
ALTF 1 Ni1000
ALTF 1 Ni1000 TK5000
ALTF 1 NTC 1.8 K, 5K, 10K, 20K, 30K, 10K Precon
ALTF 1 KTY 81-210, 81-110, 81-121, 81-122, 11-6
ALTF 1 LM235Z
Extra charge:
Accessories:
ALTF 1
- 35 ...+180 °C silicone
(T
NTC =150 °C, T
LM 235 Z = 125 °C)
max
max
(optional also with two sensors)
(4-wire connection optional)
(included in the scope of delivery)
including pre-bent contact plate
silicone, SiHF, 2 x 0,25 mm²
ends stripped, with wire end sleeves
IP 68 ( optional humidity-tight compound-filled)
®
ALTF 1 with connection cable
Sensor ⁄ Output
Pt100 (according to DIN EN 60751, class B)
Pt1000 (according to DIN EN 60751, class B)
Ni1000 (according to DIN EN 43760, class B, TCR = 6180 ppm ⁄ K)
Ni1000 TK5000 (TCR = 5000 ppm ⁄ K), LG - Ni1000
NTC 1.8 K, 5K, 10K, 20K, 30K, 10K Precon
KTY 81-210, 81-110, 81-121, 81-122, 11-6
LM235Z (TCR = 10 mV ⁄ K; 2.73 V at O °C), KP10
2-wire connecting leads (PVC) per running meter
2-wire connecting leads (silicone) per running meter
Humidity-tight compound-filled (IP 68)
Heat-conductive paste, set
1x two-wire connection
Standard
1x two-wire connection
LM 235 Z (KP 10)
1x four-wire connection
(optional)
Connecting Leads
PVC Silicone