FAULT
11. REMOTE CONTROL UNIT DOES
NOT WORK
(all other functions are OK)
12. FK 2600 COOLING UNIT DOES NOT
FUNCTION Operational readiness
indicator on cooling unit is not lit up
Warning! Where fuses need to be changed, they must be replaced by fuses of the same rating. No warranty claims will be
accepted in respect of damage caused by the use of too high a raiting of fuse!
CAUSE
Remote control cable is not properly
connected
Remote control unit or cable is faulty
10-pole remote control socket is faulty
Fuse F1 on FK 26 cooling-unit board
(No 4.070.532) is faulty
21
REMEDY
Plug in the remote control cable the right
way round,
Change the remote control unit or cable
Change the remote control socket
Change the fuse