SETTING-UP INSTRUCTIONS
DEGREE OF PROTECTION: IP23
The machine is tested to IP23, meaning that it is protected against:
- penetration by solid bodies greater than diam. 12 mm
- spray up to an angle of 60° to the vertical
OPEN-AIR OPERATION
As indicated by its protection category IP23, the machine may be
set up and operated in the open air. However, the built-in electrical
parts must be protected from direct wetting (see protection cate-
gory IP23)
COOLING AIR AND DUST
Position the machine so that the cooling air can be drawn in freely
through the louvers, and then be expelled unhindered. The cool-
ing air passes through ventilating slits in the casing into the interior
of the machine, where it cools inactive components in the ven-
tilation channel before flowing out through the ventilation outlet.
The ventilation channel has an important protective function. The
following cooling cycle is automatically controlled by an electronic
thermostatic cut-out system. (Fig. 1)
Make sure that any metal dust caused by e. g. grinding work is not
sucked into the machine by the cooling fan.
STABILITY
The power source can be stood on a surface with an inclination of
up to 15°! At inclinations above 15° there is a risk of the power
source toppling over.
WORKING WITH THE PROGRAM LEVELS
ACCESSING THE RELEVANT PROGRAM LEVEL
- With either button
or
ð
- --- appears
"Presettings" level
- Press and hold down the torch trigger until
1. --- appears ð "Presettings" level
2. P1 appears ð "Service menu" level
3. P2 appears ð "Code-lock" level
4. P3 appears ð "AC parameters" level
- Release button
or
PRESETTINGS LEVEL ---
Use button
or
to select the parameters, and the torch
trigger to change their values.
Only the parameters for the operating mode that is set (TIG/
Electrode) are shown.
Parameters for TIG DC operating mode
- GAS Gas pre-flow 0 - 20 s.
- G-L
Gas post-flow at I
min
- G-H
Gas post-flow at I
max
- UPS
Upslope 0.1 - 7 s.
- SCU Start current -
Start-arc 0-100% in DC, 0-100% in AC
- I3
Reduced current 0-100% of I
- HFt
High frequency - repetition time 0.01 - 0.4 s
- SCU Start current rel/abs
- StS
Special 2-step mode ON/OFF
- SFS
Special 4-step mode OFF/1-5
- C-C
Continuous running of cooling unit AUT/OFF/ON
- E-S
Power-source cut-off ON/OFF
- PRO Program - Pre-set parameters are stored by pressing
the torch trigger
- FAC
Factory - The parameters pre-set by Fronius are activated
by pressing the torch trigger
pressed, switch on the machine
2.0 - 26 s.
2.0 - 26 s.
H
Parameters for TIG operating mode AC
- Like in TIG operation mode DC
- Point SCU Start Current -
Start arc 30-100%
Parameters for electrode operating mode
- Hti
Hotstart time
- HCU Hotstart current
- dYn
Arcforce dynamic
- PRO Program - For storing the parameters, once these have
been set, by pressing the torch trigger
- FAC
Factory - For activating the parameters pre-set by
Fronius, by pressing the torch trigger.
In the "Electrode AC" mode, the applicable frequency is the one
set in Level 3. (The waveform in "Electrode AC" is generally a
square-wave one)
Default parameters in the Fronius program (FAC)
- E-S
OFF
- GAS
0.4s
- G-L
5.0s
- G-H
15.0
- UPS
1.0s
- SCU
DC 29%
AC 50%
- I3
50%
- HFt
0.015
- SCU
rel
- StS
OFF
- SFS
OFF
- C-C
Aut
SERVICE-MENU LEVEL P1
Service-menu with various test programs
LEVEL CODELOCK P2
The MW 2600 Fuzzy and TRANSTIG 2600CEL machines come
with an electronic codelock. The codelock is not activated when
the machines leave the factory. Whenever you change the nume-
rical combination, keep a written note of it! Only a 3-digit code may
be used. (On new machines, the code number is set to "321")
1. Procedure
- Access "Codelock level P2"
- "Cod _?_" appears on the display
- Enter the present code (on new machines, this is 321)
w Set the desired numbers with dial I
w Conform each numeral with button
w Repeat this procedure twice, until "Cod OFF" or "Cod ON"
appears on the display
From here, proceed as shown in:
2. Change and activate code
3. Deactivate code
11
0,2-2s
0-100%
0-200A
- Hti
0.5s
- HCU
50%
- dyn
40A
- ACF
60Hz
- POS
sin
- nEG
rEC
H
or