Page 1
EGEA 90 LT - 120 LT IT - MANUALE D’USO, INSTALLAZIONE E MANUTENZIONE ES - MANUAL DE USO, INSTALACIÓN Y MANTENIMIENTO EN - USER, INSTALLATION AND MAINTENANCE MANUAL PT - MANUAL DE USO, INSTALAÇÃO E MANUTENÇÃO FR - MANUEL D’UTILISATION, INSTALLATION ET ENTRETIEN...
Page 2
IT ......................3 ES ......................53 EN ....................... 105 PT ....................... 155 FR ....................... 205...
ITALIANO Lingua originale del Fabbricante. CONSERVARE PER FUTURE CONSULTAZIONI. Gentile Cliente, grazie per aver scelto un prodotto FERROLI S.p.A.. La nostra azienda, da sempre attenta alle problematiche am- DATI DEL FABBRICANTE bientali, ha utilizzato per la realizzazione dei propri prodotti, FERROLI S.p.A.
Il manuale è fornito in formato cartaceo; tut- UTILIZZANO REFRIGERANTI tavia è disponibile nella versione digitale sca- INFIAMMABILI SECONDO L’AN- ricabile dal sito www.ferroli.com selezio- NEX DD DELLA EN 60335-2-40” a nando il prodotto acquistato. pagina 47. Qualsiasi intervento sull’appa-...
Page 5
EGEA 90 LT - 120 LT • L’acqua può gocciolare dal Collegare l’apparecchiatura ad tubo di scarico del dispositivo un efficiente impianto di messa a di sovrappressione; lasciare terra. ATTENZIONE ATTENZIONE questo tubo aperto all’atmo- sfera. Non utilizzare prolunghe o adat- tatori.
“6.9 SCHEMA In mancanza di tale autorizzazione scritta, l’impiego è da con- ELETTRICO” a pagina 39 e fare ATTENZIONE siderare “uso improprio”; pertanto FERROLI S.p.A. declina riferimento anche all’interno del ogni responsabilità in relazione ai danni eventualmente provo- prodotto stesso.
Page 7
EGEA 90 LT - 120 LT nico qualificato. • Abbandonare immediatamente l’edificio, impedire l’acces- • Rispettare gli intervalli di manutenzione prescritti. so a terzi e contattare il personale di emergenza. ► PERICOLO A CAUSA DI UN UTILIZ- ► PERICOLO DI MORTE A CAUSA DEL- ZO ERRATO LE MODIFICHE AL PRODOTTO O ALL’AMBIENTE DI INSTALLAZIONE...
Page 8
EGEA 90 LT - 120 LT Il refrigerante non deve essere rilasciato nell’atmosfera. Prima di smaltire l’apparecchiatura il refrigerante in essa con- tenuto deve essere travasato in un contenitore adatto per es- sere riciclato o smaltito ai sensi delle norme vigenti. Qualsiasi intervento sull’appa- recchiatura, incluso lo smalti- mento, deve essere eseguito...
EGEA 90 LT - 120 LT DESTINATARI DEL MANUALE ISTRUZIONI PER: Esso è rivolto sia all’installatore specializzato (installatori – ma- nutentori) che all’utente finale. Per distinguere il contenuto del manuale in base alle caratteri- TECNICO ESPERTO / ASSISTENZA UTILIZZATORE stiche del destinatario (utilizzatore e tecnico esperto), le istru- TECNICA DEL FABBRICANTE zioni sono così...
L’accurata analisi fatta da FERROLI S.p.A. ha permesso di eli- ne rilevata un’incongruenza è necessario attenersi al testo in minare la maggior parte dei rischi; si raccomanda comunque di...
(RAEE). tuali errori. • Direttiva 2011/65/UE del Parlamento Europeo e del Consi- FERROLI S.p.A. non risponde di glio dell’8 giugno 2011 sulla restrizione dell’uso di deter- danni attribuibili ad errori di co- minate sostanze pericolose nelle apparecchiature elet- mando, uso improprio, uso non triche ed elettroniche (RoHS).
EGEA 90 LT - 120 LT USO DELLO SCALDABAGNO Pulire solo la superficie esterna ed il pannello di controllo uti- REGOLE FONDAMENTALI DI SICUREZZA lizzando un panno morbido ed PULIZIA asciutto. Non aprire o smontare il prodotto MANUALE quando questo è alimentato elet- tricamente.
Tasto “set” per modifica valore parametro, conferma; DELLA EN 60335-2-40” a pagina 47. Tasto “incrementa” per aumentare valore set-point, pa- FERROLI S.p.A. non si ritiene re- rametro o password Tasto “decrementa” per diminuire valore set-point, para- sponsabile per interventi esegui-...
EGEA 90 LT - 120 LT dono contemporaneamente per 3 s. IMPOSTAZIONE DELL’OROLOGIO Durante il normale funzionamento del prodotto le tre cifre del • Con tasti sbloccati, premere per 3 secondi il tasto display mostrano la temperatura dell’acqua in °C, misurata con entrare nelle impostazioni dell’orologio (il simbolo lam- la sonda acqua superiore se il parametro P11 è...
EGEA 90 LT - 120 LT Con questa modalità viene utilizzata la pompa di calore e la Set-point acqua calda Modalità resistenza elettrica, all’interno dei limiti di funzionamento del Range Default prodotto, per garantire un più veloce riscaldamento. 38÷62°C 53°C AUTOMATICO 38÷62°C 53°C...
EGEA 90 LT - 120 LT L’accensione della pompa di calore avviene 5 minuti dopo la Se la richiesta di esecuzione della funzione antilegionella av- selezione di questa modalità o dall’ultimo spegnimento. viene con la modalità VACANZA selezionata, il ciclo di anti- In caso di spegnimento, entro i primi 5 minuti, la pompa di ca- legionella verrà...
EGEA 90 LT - 120 LT Scaricare ed installare l’App "EGEA Smart" Avviare l’App "EGEA Smart" dal proprio smartphone premen- do sull’icona come sopra riportata. Registrazione utente Per utilizzare per la prima volta l’applicazione "EGEA Smart" è necessaria la registrazione dell’utente: creare un nuovo ac- count →...
Page 19
EGEA 90 LT - 120 LT fig. 5 fig. 7 Selezionare la rete Wi-Fi ed inserire la password della rete a Se la procedura di connessione con il router Wi-Fi è avvenuta cui si vuole connettere l’apparecchiatura e quindi premere con- con successo, si vedrà...
Page 20
EGEA 90 LT - 120 LT Quindi premere in corrispondenza del simbolo dell’im- magine seguente. fig. 9 Premere in corrispondenza del simbolo per selezionare, ad esempio, la modalità operativa automatico. fig. 11 Impostare la modalità operativa che si desidera durante il fun- zionamento a fasce orarie, l’ora di accensione e di spegnimen- to dell’apparecchiatura e premere il tasto conferma.
Page 21
EGEA 90 LT - 120 LT Quando il funzionamento a fasce orarie è attivato, al di fuori Impostare il numeri dei giorni di assenza e premere conferma. della fascia oraria l’apparecchiatura è in stand-by e questa è la schermata visualizzata. fig.
EGEA 90 LT - 120 LT Quindi premere conferma nella successiva schermata. 2.12 GUASTI/PROTEZIONE Questa apparecchiatura dispone di un sistema di autodiagno- si che copre alcuni possibili guasti o protezioni da condizioni anomale di funzionamento tramite: rilevamento, segnalazione e adozione di una procedura di emergenza fino risoluzione dell’anomalia.
EGEA 90 LT - 120 LT 2.13 RICERCA GUASTI Qualora si riscontra che l’apparecchiatura non funzioni correttamente, senza che vi sia alcuna segnalazione di allarme, prima di contattare l’assistenza tecnica del costruttore, è opportuno eseguire quanto segue. Anomalia Azione consigliata •...
UTILIZZATORE cato. TECNICA DEL FABBRICANTE D.P.I. NECESSARI: Le seguenti istruzioni sono rivolte al personale tecnico esperto. FERROLI S.p.A. non si ritie- ne responsabile per interven- ti eseguiti da personale non ATTENZIONE esperto e non abilitato. Qualsiasi intervento sull’appa- fig. 18...
Le targhette di tutti i componenti non costruiti direttamente da Simbolo che identifica il peso della macchina. FERROLI S.p.A. sono direttamente applicate sui componenti Se presente sull’imballo, indica il peso di ogni stessi, nei punti dove i rispettivi fabbricanti le hanno collocate collo.
EGEA 90 LT - 120 LT Simbolo Definizione Termine Definizione FRAGILE Operazioni periodiche allo scopo di verifi- Apposto sull’imballo indica di manipolarlo MANUTENZIONE care il corretto funzionamento (esempio: con cura onde evitare eventuali rotture al pulizia) rivolte all’addetto qualificato. contenuto. LIMITAZIONE SOVRAPPOSIZIONE DISPOSITIVI DI PROTEZIONE INDIVIDUALE...
EGEA 90 LT - 120 LT MOVIMENTAZIONE E TRASPORTO RISCHI RESIDUI La progettazione è stata eseguita in modo da garantire i requi- MOVIMENTAZIONE DELL’IMBALLO siti essenziali di sicurezza per l’operatore addetto e per l’utente L’apparecchiatura viene fornita in una scatola di cartone su finale.
EGEA 90 LT - 120 LT CARATTERISTICHE COSTRUTTIVE RICEVIMENTO Oltre alle unità all’interno degli imballi sono contenuti accessori IDENTIFICAZIONE DEI COMPONENTI e documentazione tecnica per l’uso e l’installazione. • Verificare che siano presenti i seguenti componenti: RIF. DESCRIZIONE (fig. 20 - fig. 21 - fig. 22) - Manuale d’Uso, Installazione e Manutenzione Pompa di calore - Valvola di sicurezza...
EGEA 90 LT - 120 LT INSTALLAZIONE E MESSA IN SERVI- O in applicazioni che richiedono un grado superiore a IP24 o che richiedono caratteristiche di si- L’installazione, la messa in servizio e la manutenzione del ATTENZIONE curezza (fault-tolerant, fail-safe) prodotto devono essere eseguite da personale qualifi- quali possono essere impianti cato e autorizzato.
EGEA 90 LT - 120 LT 6.3.2 Condizioni ambientali per il funzionamento In fase di progettazione e costru- zione degli impianti vanno rispet- L’apparecchiatura non può ope- tate le norme e disposizioni vi- rare in locali classificati come OBBLIGO genti a livello locale. ambienti con atmosfera esplosi- DIVIETO L’ingresso ed uscita dell’aria...
EGEA 90 LT - 120 LT FISSAGGIO A MURO COLLEGAMENTI AERAULICI Il prodotto deve essere installato su una parete solida, non La pompa di calore necessita, oltre agli spazi indicati nel para- soggetta a vibrazioni. Per il fissaggio scegliere il tipo di tassello grafo 6.4, di un’adeguata ventilazione d’aria.
EGEA 90 LT - 120 LT COLLEGAMENTI IDRAULICI Tubo lineare Curva 90° Dato Griglia liscio liscia • Collegare la linea di alimentazione d’acqua fredda e la linea in uscita negli appositi punti di allacciamento (fig. 33). Tipo Lunghezza effettiva Lunghezza equivalente •...
EGEA 90 LT - 120 LT • L’acqua può gocciolare dal tubo di scarico del disposi- tivo di sovrappressione; la- ATTENZIONE sciare questo tubo aperto all’atmosfera. • Il dispositivo di decompres- sione deve essere azionato regolarmente per rimuovere i depositi di calcare e per ve- rificare che non sia bloccato.
EGEA 90 LT - 120 LT Gli apparecchi fissi non sono do- tati di mezzi di disconnessione dalla rete di alimentazione con ATTENZIONE una separazione dei contatti su tutti i poli in grado di garantire la disconnessione completa nella categoria di sovratensione III, le istruzioni indicano che i mezzi di disconnessione debba- 60mm...
Page 38
EGEA 90 LT - 120 LT 1 per attivare il supplemento con fotovoltaico. • Digitale 3 (DIG3). Ingresso per l’Off-Peak. Questa funzione disponibile solo in alcuni paesi permette di attivare il l’ap- parecchiatura solo in presenza di un segnale proveniente dall’esterno con tariffa agevolata.
Centro as- asciutto. PULIZIA MANUALE sistenza tecnica autorizzato FERROLI S.p.A. nel periodo di garanzia convenzionale per problematiche di prodotto riconducibili ad 6.10.3 Messa in servizio dell’impianto errate impostazioni dei parametri protetti da •...
Page 41
EGEA 90 LT - 120 LT mediante i tasti “+” e “-” è possibile modificarne il valore all’interno del range ammissibile per questo parametro. Quindi premere per confermare e il tasto “+” per proseguire con gli altri parametri. Dopo aver modificato i parametri che si desiderano, premere il tasto on/off per salvare ed uscire. A questo punto l’apparecchiatura ritorna in stand-by.
Page 42
EGEA 90 LT - 120 LT Parametro Descrizione Range Default Note 0 = EC Tipo di ventilatore dell’evaporatore (EC; AC; 1 = AC AC due velocità; EC con controllo dinamico 2 = AC a due velocità Modificabile della velocità) 3 = EC con controllo dinamico della velocità...
Page 43
EGEA 90 LT - 120 LT Parametro Descrizione Range Default Note 0 = non utilizzata Utilizzo EEV Modificabile 1 = utilizzata Intervallo calcolo surriscaldamento per EEV 20÷90s 30 s Modificabile con controllo automatico Setpoint surriscaldamento per EEV con con- -8÷15°C 3°C Modificabile trollo automatico...
Page 44
EGEA 90 LT - 120 LT Parametro Descrizione Range Default Note Regolazione proporzionale temperatura eva- 1÷20°C 4°C Modificabile poratore banda 1 Temperatura differenziale con attivazione P57÷20°C 2°C Modificabile della massima velocità Temperatura differenziale con disattivazione 1°C÷P56 1°C Modificabile della massima velocità 0 = OFF 1 = ON con controllo manuale Uso del ventilatore dell'evaporatore con il...
EGEA 90 LT - 120 LT SOSTITUZIONI SOSTITUZIONE FUSIBILE SCHEDA DI POTENZA Procedere come di seguito indicato (riservato solo a personale Riparazioni improprie possono tecnico qualificato): porre l’utente in serio pericolo. • Togliere l’alimentazione elettrica all’apparecchiatura. Se la vostra apparecchiatura ATTENZIONE •...
EGEA 90 LT - 120 LT Prima di eseguire la verifica è necessario: • Chiudere la mandata d’ingresso dell’acqua fredda. • Procedere con lo svuotamento dell’acqua del boiler (vedere paragrafo “7.4 SVUOTAMENTO DEL BOILER”). • Rimuovere il coperchio inferiore 1. •...
EGEA 90 LT - 120 LT SOSTITUZIONE DEL CAVO DI ALIMENTAZIO- Non forare o bruciare. NON MANOMETTERE IL CAVO OBBLIGO DI ALIMENTAZIONE. Se il cavo di alimentazione è ATTENZIONE Fare attenzione al fatto che i flui- danneggiato, esso deve essere di frigorigeni possono non avere sostituito dal costruttore o dal odore.
EGEA 90 LT - 120 LT Il prodotto risulta sprovvisto di valvola di carica o di ri-carica in Verificare periodicamente che quanto tale operazione non può e non deve essere eseguita non vi siano ostruzioni nelle per alcuna ragione in utenza. Nel caso si verifichi la presenza aperture atte a garantire il ricam- di una perdita sul circuito frigorifero o nel caso lo stesso risul- bio d’aria all’interno del locale di...
EGEA 90 LT - 120 LT Ricerca fughe Prima di procedere con lo smaltimento del prodotto è neces- • Non utilizzare fiamme di alcun genere per rilevare la fuoriu- sario rimuovere in sicurezza il gas refrigerante dal circuito, scita di gas refrigerante. questa operazione deve essere eseguita in conformità...
EGEA 90 LT - 120 LT I principali materiali che compongono l’apparecchiatura in oggetto sono: • acciaio - magnesio - plastica - rame - alluminio - poliuretano INFORMAZIONE AGLI UTILIZZATORI Ai sensi delle Direttive 2011/65/EU e 2012/19/EU relative alla riduzione dell‘uso di sostanze pericolose nelle apparec- chiature elettriche ed elettroniche, nonché...
EGEA 90 LT - 120 LT 11. NOTE SUI DISPOSITIVI RADIO E APP Questo prodotto incorpora un modulo radio (Wi-Fi) ed è conforme alla direttiva RED (Radio Equipment Directive) 2014/53/EU. Di seguito sono indicati i principali dati della parte radio: •...
Modalità per far valere la presente Garanzia In caso di guasto, il cliente deve richiedere entro il termine di decadenza di 30 giorni l’intervento del Centro di Assistenza di zona, autorizzato Ferroli S.p.A.. I nominativi dei Centri di Assistenza autorizzati Ferroli S.p.A. sono reperibili: •...
Traducción del idioma original del Fabricante. Estimado Cliente: CONSERVAR PARA FUTURAS CONSULTAS. gracias por haber escogido un producto FERROLI S.p.A.. Nuestra empresa, desde siempre atenta a la problemática am- DATOS DEL FABRICANTE biental, utiliza para la fabricación de sus productos tecnologías FERROLI S.p.A.
EGEA 90 LT - 120 LT ADVERTENCIAS DE SEGURIDAD Antes de realizar cualquier tipo de intervención en el aparato el personal encargado del manteni- miento debe consultar lo indica- Leer atentamente antes de la insta- do en los siguientes capítulos en lación y el uso del aparato.
Page 55
EGEA 90 LT - 120 LT • El agua puede gotear del tubo Conectar el aparato a un sistema de drenaje del dispositivo de eficaz de puesta a tierra. alivio de presión; dejar este ATENCIÓN ATENCIÓN tubo abierto a la atmósfera. No utilizar alargadores ni adapta- •...
En ausencia de dicha autorización escrita, el empleo se consi- QUEMA ELÉCTRICO” en la pá- ATENCIÓN dera “uso inadecuado”; por lo tanto FERROLI S.p.A. declina gina 89 y consultar además el toda responsabilidad por los daños causados a los bienes o a interior del producto mismo.
Page 57
EGEA 90 LT - 120 LT ► PELIGRO A CAUSA DE UN USO ► PELIGRO DE MUERTE A CAUSA DE ERRADO LAS MODIFICACIONES AL PRODUC- TO O AL AMBIENTE DE INSTALACIÓN Tras una orden errada es posible poner en riesgo a sí mismos y otras personas y causar daños materiales.
Page 58
EGEA 90 LT - 120 LT El refrigerante no debe ser liberado a la atmósfera. Antes de eliminar el aparato el refrigerante que contiene debe ser trasvasarse en un recipiente adecuado para ser reciclado o eliminado de acuerdo con las normas vigentes. Cualquier intervención en el aparato, incluida la elimina- ción, debe ser realizada por...
EGEA 90 LT - 120 LT DESTINATARIOS DEL MANUAL INSTRUCCIONES PARA: El manual está dirigido al instalador especializado (instalado- res – técnicos de mantenimiento) y al usuario final. Para distinguir el contenido del manual en base a las caracte- TÉCNICO EXPERTO / ASISTENCIA USUARIO rísticas del destinatario (usuario y técnico experto), las instruc- TÉCNICA DEL FABRICANTE...
— Registered symbols. FERROLI S.p.A. se reserva el derecho de aportar modificacio- • UNI EN ISO 7010:2021 - Signos gráficos - Colores y seña- nes, cambios o mejorías en el manual o en las máquinas, en les de seguridad - Señales de seguridad registradas...
8 de junio de 2011 sobre la restricción del uso de ciertas sustancias peligrosas en los equipos eléctricos y electrónicos (RoHS). FERROLI S.p.A. no responde por daños atribuibles a errores de • Directiva 2014/30/UE del Parlamento Europeo y del Con- mando, uso inadecuado, uso in- ATENCIÓN...
EGEA 90 LT - 120 LT USO DEL CALENTADOR DE AGUA Limpiar solo la superficie externa y el panel de control utilizando REGLAS FUNDAMENTALES DE SEGURIDAD un paño suave y seco. LIMPIEZA No abrir ni desmontar el aparato MANUAL cuando esté conectado a la co- rriente.
Tecla “set” para modificar el valor el parámetro y con- 60335-2-40” en la página 97. firmar; Tecla “incrementa” para aumentar el valor de consigna, FERROLI S.p.A. no se considera parámetro o contraseña responsable por intervenciones Tecla “decrementa” para disminuir el valor de consigna, realizadas por personal no ex- parámetro o contraseña...
EGEA 90 LT - 120 LT Durante el funcionamiento normal del aparato, los tres dígitos CONFIGURACIÓN DEL RELOJ de la pantalla muestran la temperatura del agua en °C, medida • Con las teclas desbloqueadas, pulsar durante 3 segundos con la sonda de agua superior si el parámetro P11 = 1 o con la la tecla para entrar en el ajuste del reloj (el símbolo sonda de agua inferior si P11 = 0.
EGEA 90 LT - 120 LT En esta modalidad se utilizan la bomba de calor y la resisten- Temperatura de consigna del agua caliente Modos cia eléctrica, dentro de los límites de funcionamiento del apa- Campo Predeterminado rato, para garantizar un calentamiento más rápido. 38 ÷...
EGEA 90 LT - 120 LT confort posible. y se vuelve a activar a las 2 semanas. El encendido de la bomba de calor se produce 5 minutos des- Si la solicitud de ejecución de la función antilegionela se pro- pués de seleccionar este modo o del último apagado.
Page 68
EGEA 90 LT - 120 LT Descargar e instalar la Aplicación "EGEA Smart" Iniciar la Aplicación "EGEA Smart" desde el smartphone pre- sionando el icono ilustrado más arriba. Registro de usuario Para utilizar por primera vez la aplicación "EGEA Smart" es necesario hacer el registro del usuario: crear una nueva cuen- ta →...
Page 69
EGEA 90 LT - 120 LT fig. 5 fig. 7 Seleccionar la red Wi-Fi e introducir la contraseña de la red a Si el procedimiento de conexión con el router Wi-Fi se ejecuta la cual se desee conectar el aparato y pulsar confirmar en la correctamente, el dispositivo aparece añadido como se ilustra aplicación.
Page 70
EGEA 90 LT - 120 LT A continuación pulsar el símbolo de la imagen si- guiente. fig. 9 Pulsar el símbolo para seleccionar, por ejemplo, el modo de funcionamiento automático. fig. 11 Configurar el modo de funcionamiento deseado para el uso de franjas horarias, ajustar el horario de encendido y apagado del aparato y pulsar la tecla Confirmar.
Page 71
EGEA 90 LT - 120 LT Cuando está activado el funcionamiento con franjas horarias, Configurar el número de días de ausencia y pulsar Confirmar. fuera de la franja horaria el aparato está en espera y se visua- liza esta pantalla. fig.
EGEA 90 LT - 120 LT Pulsar Confirmar en la pantalla siguiente. 2.12 FALLOS/PROTECCIÓN Este aparato dispone de un sistema de autodiagnóstico que analiza algunos fallos y protecciones contra anomalías de fun- cionamiento mediante: detección, aviso y adopción de un pro- cedimiento de emergencia hasta la resolución de la anomalía.
EGEA 90 LT - 120 LT 2.13 LOCALIZACIÓN DE FALLOS Si el aparato no funciona correctamente, aunque no haya señales de alarma, antes de contactar con la asistencia técnica del fa- bricante, se recomienda seguir estas indicaciones. Anomalía Acción recomendada •...
TÉCNICO EXPERTO / ASISTENCIA USUARIO TÉCNICA DEL FABRICANTE D.P.I. NECESARIOS: Las siguientes instrucciones están dirigidas al personal técnico experto. FERROLI S.p.A. no se consi- dera responsable por interven- ciones realizadas por personal ATENCIÓN no experto y no habilitado. Cualquier intervención en el fig.
Símbolo que identifica el peso de la máquina. Las placas de todos los componentes no fabricados directa- Si está en el embalaje, indica el peso de cada mente por FERROLI S.p.A. están directamente aplicadas en bulto. los mismos componentes, en los puntos donde los respectivos fabricantes las colocaron originalmente.
EGEA 90 LT - 120 LT DISPOSITIVOS DE PROTECCIÓN INDIVIDUAL Símbolo Definición La indumentaria de quien opera o realiza el mantenimiento LIMITACIÓN DE SUPERPOSICIÓN DE debe estar conforme con los requisitos esenciales de seguri- LOS EMBALAJES dad definidos por las leyes vigentes en el país donde el mismo Colocado en el embalaje indica no es instalado.
EGEA 90 LT - 120 LT DESPLAZAMIENTO Y TRANSPORTE RIESGOS RESIDUALES El diseño ha sido realizado de modo de garantizar los requi- DESPLAZAMIENTO DEL EMBALAJE sitos esenciales de seguridad para el operador encargado y El aparato se suministra en una caja de cartón sobre un palé para el usuario final.
EGEA 90 LT - 120 LT CARACTERÍSTICAS RECEPCIÓN CONSTRUCTIVAS Además de las unidades, los embalajes contienen accesorios y documentación técnica para el uso y la instalación. IDENTIFICACIÓN DE LOS COMPONENTES • Comprobar la presencia de los elementos siguientes: - Manual de uso, instalación y mantenimiento REF.
EGEA 90 LT - 120 LT INSTALACIÓN Y PUESTA EN O en aplicaciones que requieren MARCHA un grado superior a IP24 o que requieren características de se- La instalación, la puesta en marcha y el mantenimiento del ATENCIÓN guridad (fault-tolerant, fail-safe) aparato deben ser efectuados por personal cualificado como sistemas y/o tecnologías y autorizado.
EGEA 90 LT - 120 LT 6.3.2 Condiciones ambientales para el funcionamiento En fase de diseño y fabricación de los sistemas deben respetar- El aparato no puede operar en se las normas y disposiciones vi- locales clasificados como am- OBLIGACIÓN gentes a nivel local.
EGEA 90 LT - 120 LT FIJACIÓN EN LA PARED CONEXIONES AERÁULICAS El aparato se debe fijar a una pared firme que no esté sujeta La bomba de calor necesita, además de los espacios indica- a vibraciones. Para la fijación, utilizar los tacos de expansión dos en el apartado 6.4, una adecuada ventilación de aire.
EGEA 90 LT - 120 LT CONEXIONES HIDRÁULICAS Tubo lineal Dato Codo 90° liso Rejilla liso • Conectar la línea de alimentación de agua fría y la línea de salida a los puntos de conexión (fig. 33). Tipo Longitud efectiva Longitud equivalente •...
Page 86
EGEA 90 LT - 120 LT • El agua puede gotear del tubo de drenaje del dispositivo de alivio de presión; dejar este ATENCIÓN tubo abierto a la atmósfera. • El dispositivo de descom- presión debe accionarse re- gularmente para remover los depósitos de cal y para veri- ficar que no esté...
EGEA 90 LT - 120 LT Los aparatos fijos no están dota- dos de medios de desconexión de la red de alimentación con una ATENCIÓN separación de los contactos en todos los polos capaz de garan- tizar la desconexión completa en la categoría de sobretensión III, las instrucciones indican que los medios de desconexión de-...
EGEA 90 LT - 120 LT • Digital 3 (DIG3). Entrada para Off-Peak (horas valle). Esta función, disponible sólo en algunos países, permite activar el aparato sólo en presencia de una señal proveniente del ex- terior, a una tarifa reducida. Si el contactor eléctrico dispone de un contacto seco que se cierra cuando está...
Centro de asistencia técnica LIMPIEZA MANUAL autorizado FERROLI S.p.A. durante el perío- do de garantía convencional por problemas debidos a una configuración errónea de los 6.10.3 Puesta en marcha del sistema parámetros protegidos por contraseña están...
Page 91
EGEA 90 LT - 120 LT las teclas “+” y “-” es posible modificar el valor dentro del rango admisible para este parámetro. Luego pulsar para confirmar y la tecla “+” para continuar con los otros parámetros. Después de modificar los parámetros deseados, pulsar la tecla on/off para guardar y salir. El aparato se vuelve a poner en espera.
Page 92
EGEA 90 LT - 120 LT Parámetro Descripción Campo Predeterminado Notas 0 = EC Tipo de ventilador del evaporador (EC; AC; 1 = AC AC dos velocidades; EC con control dinámi- 2 = AC dos velocidades Modificable co de la velocidad) 3 = EC con control dinámico de la velocidad 0 = NC...
Page 93
EGEA 90 LT - 120 LT Parámetro Descripción Campo Predeterminado Notas 0 = no utilizada Uso EEV Modificable 1 = utilizada Intervalo cálculo sobrecalentamiento para 20 ÷ 90 s 30 s Modificable EEV con control automático Consigna sobrecalentamiento para EEV con -8 ÷...
Page 94
EGEA 90 LT - 120 LT Parámetro Descripción Campo Predeterminado Notas Regulación proporcional temperatura evapo- 1 ÷ 20 °C 4°C Modificable rador banda 1 Temperatura diferencial con activación de la P57÷20°C 2°C Modificable máxima velocidad Temperatura diferencial con desactivación 1°C÷P56 1°C Modificable de la máxima velocidad...
EGEA 90 LT - 120 LT SUSTITUCIONES SUSTITUCIÓN FUSIBLE TARJETA DE POTENCIA Proceder de la siguiente manera (sólo para personal técnico reparación incorrecta autorizado): puede implicar peligros para el • Desconectar la alimentación eléctrica del aparato. usuario. Si su aparato necesita ATENCIÓN •...
EGEA 90 LT - 120 LT Antes de realizar la verificación es necesario: • Cerrar la entrada de agua fría. • Vaciar el acumulador (ver el apartado “7.4 VACIADO DEL ACUMULADOR”). • Quitar la tapa inferior 1. • Desconectar de la tarjeta de potencia la conexión eléctrica del termostato de seguridad de la resistencia, y extraer las sondas NTC del agua del tubo situado en la brida de la re- sistencia.
EGEA 90 LT - 120 LT SUSTITUCIÓN DEL CABLE DE ALIMENTACIÓN No perforar ni quemar. NO MANIPULAR EL CABLE DE OBLIGACIÓN ALIMENTACIÓN. Si el cable de alimentación está ATENCIÓN dañado, debe ser sustituido por Tener en cuenta que los fluidos el fabricante o por el servicio de frigoríficos pueden no tener olor.
EGEA 90 LT - 120 LT El aparato no está provisto de válvula de carga o recarga por- Verificar periódicamente que no que está operación no debe ser realizada en ningún caso por haya obstrucciones en las aber- el usuario. Si se verifica una fuga en el circuito frigorífico, o si turas que permiten el recambio este se encuentra parcial o totalmente vacío de gas refrigeran- de aire en el local de instalación.
EGEA 90 LT - 120 LT Localización de fugas Antes de proceder con la eliminación, es necesario retirar de • No utilizar llamas de ningún tipo para detectar fugas de gas forma segura el gas refrigerante del circuito; esta operación refrigerante.
EGEA 90 LT - 120 LT Principales materiales de composición del aparato: • acero - magnesio - plástico - cobre - aluminio - poliuretano INFORMACIÓN PARA LOS USUARIOS Según las directivas 2011/65/EU y 2012/19/EU sobre la reducción del uso de sustancias peligrosas en los aparatos eléctricos y electrónicos y los requisitos para su desecho.
EGEA 90 LT - 120 LT 11. NOTAS SOBRE LOS DISPOSITIVOS Y APP Este producto incorpora un módulo radio (Wi-Fi) y cumple con la directiva RED (Radio Equipment Directive) 2014/53/EU. A conti- nuación se muestran los principales datos de la parte de radio: •...
El período de Garantía para los equipos de aire acondicionado afectados por este documento es de 2 años de Garantía Total a partir de la fecha de factura de venta, siempre y cuando haya sido instalado en un plazo máximo de 12 meses desde la fecha de expedición y salida de los almacenes de Ferroli España. ALCANCE La Garantía contempla:...
Page 103
SAT Central de FERROLI ESPAÑA dentro de las 24 horas siguientes a la misma, según la fecha indicada en el albarán de entrega. De no disponer del registro de tal reclamación, FERROLI ESPAÑA no asumirá...
Page 104
EGEA 90 LT - 120 LT DATOS A CUMPLIMENTAR POR EL CLIENTE Datos del CLIENTE Apellidos: Nombre: Calle: Nº C.P.: Ciudad: Provincia: Datos del EQUIPO Fecha de Compra: Sello de la empresa que realiza la instalación Apuntar aquí los códigos de serie / fabricación adjuntos con la máquina cód.
For any request for TECHNICAL ASSISTANCE on the ma- user/owner. chine, refer to the following contacts. In the event of loss of or damage to this manual, another copy can be downloaded from the website www.ferroli.com by se- For the service centre, visit: lecting the purchased product. www.ferroli.com The images are for illustrative purpose only and do not consti- tute a commitment for the manufacturer and/or the Distributor.
ACCORDING TO ANNEX DD OF ever, it is available in digital version, which EN 60335-2-40” on page 149. can be downloaded from the website www. ferroli.com by selecting the purchased product. During the design and construc- tion phase of the systems, local...
Page 107
EGEA 90 LT - 120 LT • Water can drip from the dis- Connect the device to an efficient charge pipe of the overpres- grounding system. sure device; leave this pipe ATTENTION ATTENTION open to the atmosphere. Do not use extension cords or •...
In the absence of such written authorisation, the use is to be Before carrying out any repairs considered “improper use”; therefore FERROLI S.p.A. de- to the product, carefully read the clines all responsibility in relation to any damage caused to wiring diagram shown in chapt.
Page 109
EGEA 90 LT - 120 LT ► DANGER DUE TO MISUSE described in this manual (ref. chapter 6 on page 134). • Never remove, tamper with, bypass or block the safety An incorrect command can put yourself and others at risk and devices.
Page 110
EGEA 90 LT - 120 LT The refrigerant gas must not be released into the atmos- phere. Before disposing of the device, the refrigerant gas contained in it must be poured into a suitable container to be recycled or disposed of in accordance with current regulations. Any intervention on the de- vice, including disposal, must be performed by qualified per-...
Page 111
EGEA 90 LT - 120 LT SUMMARY VIBRATIONS ............128 INSTRUCTIONS FOR: RESIDUAL RISKS ..........129 4. HANDLING AND TRANSPORT ......129 HANDLING OF PACKAGING ....... 129 UNPACKING ............129 EXPERT TECHNICIAN / RECEIPT ............... 130 USER MANUFACTURER'S TECHNICAL ASSISTANCE 5.
EGEA 90 LT - 120 LT RECIPIENTS OF THE MANUAL INSTRUCTIONS FOR: It is intended for the specialist installer (installers - mainte- nance technicians) and the end user. To distinguish the content of the manual based on the char- EXPERT TECHNICIAN / USER acteristics of the recipient (user and expert technician), the in- MANUFACTURER'S TECHNICAL...
Technical Documentation Office. The careful analysis carried out by FERROLI S.p.A. has made it possible to eliminate most of the risks; however, it is recom- DECLARATION OF CONFORMITY mended to strictly follow the instructions given in this docu- ment.
Except in the case of errors. • Directive 2012/19/EU of the European Parliament and of the Council OF 4 July 2012 on waste electrical and electronic FERROLI S.p.A. is not liable for device (WEEE). damage attributable to operating errors, improper use, inappropri- •...
EGEA 90 LT - 120 LT USE OF THE WATER HEATER Clean only the external surface and the control panel using a BASIC SAFETY RULES soft, dry cloth. MANUAL Do not open or disassemble the CLEANING product when it is electrically powered.
"On/Off" button for switching on, putting the product in standby mode, unlocking buttons, saving changes ANNEX DD OF EN 60335-2-40” on page 149. "Set" button to edit the parameter value, confirm; FERROLI S.p.A. cannot be held “Increase” key to increase the set-point value, parame- responsible interventions...
EGEA 90 LT - 120 LT The user interface of this water heater model consists of four SETTING THE CLOCK capacitive buttons, and a LED display. • With the buttons unlocked, press button for 3 seconds to As soon as the water heater is powered the four buttons are access the clock settings (the symbol flashes).
EGEA 90 LT - 120 LT considered only for the heating element. With this mode only the heating element is used within the product operating limits and is useful in situations of low inlet air temperatures. OPERATING MODE The following modes are available for this water heater: - ECO;...
EGEA 90 LT - 120 LT mode is not operating and the unit works in the set mode: ECO, Defrosting occurs through the injection of hot gas into the AUTOMATIC or HOLIDAY. evaporator, allowing it to be rapidly defrosted. When the symbol on the display is lit up, the energy pro- During defrosting, the heating element, which the equipment duced by the photovoltaic system is used to heat the water...
EGEA 90 LT - 120 LT User registration To use the "EGEA Smart" application for the first time, user registration is required: create a new account → enter the mo- bile number/email address → enter the verification code and set the password → confirm. fig.
Page 121
EGEA 90 LT - 120 LT fig. 5 fig. 7 Select the Wi-Fi network and enter the password of the net- If the procedure for connection with the Wi-Fi router was suc- work for connecting the equipment, then press confirm on the cessful, you will see your device added as shown below.
Page 122
EGEA 90 LT - 120 LT fig. 9 fig. 11 Press on the symbol to select, for example, the automatic Set the operating mode desired during time band operation, the operating mode. equipment switch-on and switch-off time and press the confirm button.
Page 123
EGEA 90 LT - 120 LT played. fig. 15 fig. 13 To disable the holiday mode before its end, press the holiday Holiday mode can be activated in any operating mode by press- mode "disable" button. ing on the symbol .
EGEA 90 LT - 120 LT 2.12 FAULTS/PROTECTION This device has a self-diagnosis system that covers some pos- sible faults or protections from anomalous operating conditions through: detection, signalling and adoption of an emergency procedure until resolution of the fault. Display indi- Fault/Protection Error code...
EGEA 90 LT - 120 LT 2.13 TROUBLESHOOTING If the equipment is not working properly, without any alarm signaling, before contacting the manufacturer's technical assistance service, it is advisable to carry out the following. Malfunction Recommended action • Check that the plug is properly inserted in the socket. •...
EXPERT TECHNICIAN / USER MANUFACTURER'S TECHNICAL ASSISTANCE P.P.E. NEEDED: The following instructions are intended for experienced technical personnel. FERROLI S.p.A. cannot be held responsible for interven- tions carried out by non-expert ATTENTION and non-qualified personnel. fig. 18 Any intervention on the de- vice, including disposal, must REF.
The labels of all components not built directly by chine. If present on the packaging, it indicates FERROLI S.p.A. are directly applied to the components them- the weight of each package. selves, in the points where the respective manufacturers orig- inally placed them.
EGEA 90 LT - 120 LT PERSONAL PROTECTIVE EQUIPMENT Symbol Definition The clothes worn by people who work or carry out maintenance LIMITATION OF PACKAGING OVERLAP work must comply with the essential safety requirements de- Affixed to the packaging, it indicates not to fined by the laws in force in the country in which it is installed.
EGEA 90 LT - 120 LT HANDLING AND TRANSPORT RESIDUAL RISKS The design was carried out in order to ensure the essential HANDLING OF PACKAGING safety requirements for the operator in charge and for the end The device comes in a cardboard box on a wooden pallet. user.
EGEA 90 LT - 120 LT CONSTRUCTION RECEIPT CHARACTERISTICS In addition to the units, the packages contain accessories and technical documentation for use and installation. COMPONENT IDENTIFICATION • Check that the following are present: - User, Installation and Maintenance Manual REF.
EGEA 90 LT - 120 LT TECHNICAL FEATURES Model 90 LT 120 LT 230-1-50 Power supply V-f-Hz Thermal power (UNI) Total absorbed power in heating (UNI) COP (UNI) 3.08 3.08 1.25 1.25 Rated current in heating (UNI) Max. total absorbed power in heating 1.74 1.74 Max.
EGEA 90 LT - 120 LT INSTALLATION AND Or for applications that require a COMMISSIONING degree higher than IP24 or that require safety features (fault-tol- Product installation, commissioning and maintenance ATTENTION erant, fail-safe) such as life sup- must be carried out by qualified and authorised per- port systems and/or technolo- sonnel.
EGEA 90 LT - 120 LT 6.3.2 Environmental conditions for operation During the design and construc- tion phase of the systems, local The device cannot operate in rules and regulations must be rooms classified as environ- OBLIGATION complied with. ments with an explosive atmos- PROHIBITION The air inlet and outlet of the ap- phere or at risk of fire.
EGEA 90 LT - 120 LT WALL FIXING AERAULIC CONNECTIONS The product must be installed on a solid wall that is not subject In addition to the spaces indicated in section 6.4, the heat to vibrations. For securing choose the most suitable type of pump requires adequate air ventilation.
EGEA 90 LT - 120 LT HYDRAULIC CONNECTIONS Smooth Smooth 90 ° Data Grille straight pipe curve • Connect the cold water supply line and the outlet line to the appropriate connection points (fig. 33). Type Effective length Equivalent length •...
EGEA 90 LT - 120 LT • Water can drip from the dis- charge pipe of the overpres- sure device; leave this pipe ATTENTION open to the atmosphere. • The decompression device must be operated regularly to remove limescale depos- its and to check that it is not blocked.
EGEA 90 LT - 120 LT Fixed devices are not equipped with means of disconnection from the mains with a separation ATTENTION of the contacts on all poles ca- pable of guaranteeing complete disconnection in the overvolt- age category III, the instruc- tions indicate that the means of disconnection must be integrat- 60mm...
Page 140
EGEA 90 LT - 120 LT • Digital 3 (DIG3). Input for Off-Peak. This function, available only in some countries, allows the equipment to be activated only when there is a signal coming from outside with prefer- ential tariff. If the electric contactor has a voltage-free contact which closes when the preferential tariff is available, it can be connected to the two grey and pink wires of the 6-core cable supplied with the device.
Clean only the external surface er from an authorised technical assistance using a soft and dry cloth. MANUAL centre FERROLI S.p.A. during the standard CLEANING warranty period, for product problems due to incorrect settings of password-protected pa- rameters, will not be covered by the standard 6.10.3 System commissioning...
Page 143
EGEA 90 LT - 120 LT rameter which can be modified by pressing , and using the “+” and “-” buttons it is possible to change the value within the per- missible range for this parameter. Then press to confirm and “+” button to continue with the other parameters. After editing the desired parameters, press the on/off button to save and exit.
Page 144
EGEA 90 LT - 120 LT Parame- Description Range Default Notes ters 0 = EC 1 = AC Type of evaporator fan (EC; AC; AC with double 2 = AC with double speed Modifiable speed; EC with dynamic speed control) 3 = EC with dynamic speed control 0 = NC...
Page 145
EGEA 90 LT - 120 LT Parame- Description Range Default Notes ters 0 = permanently deactivated Electronic-expansion valve (EEV) control Modifiable 1 = activated Superheating calculation period for EEV auto- 20÷90s 30 s Modifiable matic control mode Superheating setpoint for EEV automatic control -8÷15°C 3°C Modifiable...
Page 146
EGEA 90 LT - 120 LT Parame- Description Range Default Notes ters Band 1 evaporator temperature proportional 1÷20°C 4°C Modifiable regulation Differential temperature with activation of max- P57÷20°C 2°C Modifiable imum speed Differential temperature with deactivation of 1°C÷P56 1°C Modifiable maximum speed 0 = OFF 1 = ON with manual speed...
EGEA 90 LT - 120 LT REPLACEMENTS POWER BOARD FUSE REPLACEMENT Proceed as indicated below (reserved for qualified technical Incorrect repairs may put the personnel only): user in serious danger. If your • Disconnect the power to the device. device needs any repair, con- ATTENTION •...
EGEA 90 LT - 120 LT Before carrying out the check, you must: • Close the cold water inlet. • Proceed with emptying the boiler (see par. “7.4 EMPTYING THE BOILER”). • Remove the bottom cover 1. • Disconnect the heating element safety thermostat electri- cal connection from the power board and remove the water NTC probes from the dedicated pipe in the element flange.
EGEA 90 LT - 120 LT REPLACEMENT OF THE POWER CORD DO NOT TAMPER WITH THE Do not pierce or burn. POWER CORD. OBLIGATION If the power supply cable is dam- ATTENTION aged, it must be replaced by the manufacturer or the technical as- Remember that refrigerant fluids sistance service or in any case may be odorless.
EGEA 90 LT - 120 LT The product does not have a charging or recharging valve, as Periodically check that there are this operation cannot and must not be performed for any rea- no obstructions in the openings son on site. In case of a leak in the refrigeration circuit or if it that ensure the change of air in- is partially or entirely empty, the maintenance technician must side the installation room.
EGEA 90 LT - 120 LT Leak detection Before proceeding with the disposal of the product, it is nec- • Do not use any kind of flame to detect refrigerant leakage. essary to safely remove the refrigerant gas from the circuit; •...
EGEA 90 LT - 120 LT The main materials that make up the device in question are: • steel - magnesium - plastic - copper - aluminium - polyurethane USER INFORMATION Pursuant to Directives 2011/65/EU and 2012/19/EU on the restriction of the use of hazardous substances in electrical and electronic equipment, as well as the disposal of waste.
EGEA 90 LT - 120 LT 11. NOTES ON RADIO DEVICES AND APPS This product incorporates a radio module (Wi-Fi) and complies with the RED (Radio Equipment Directive) 2014/53/EU. The follow- ing are the main data of the radio part: •...
Page 155
Tradução da idioma original do Fabricante. Estimado cliente, CONSERVAR PARA CONSULTAS FUTURAS. Agradecemos-lhe ter escolhido um produto FERROLI S.p.A.. A nossa empresa, desde sempre atenta às questões ambien- DADOS DO FABRICANTE tais, utilizou, para a realização dos respetivos produtos, tecno- FERROLI S.p.A.
DE ACORDO COM O ANEXO DD pode ser descarregada a partir do site www. DA EN 60335-2-40” na página ferroli.com selecionando o produto com- 199. prado. Na fase de conceção e fabrico Qualquer intervenção no equipa- dos sistemas devem respeitar-se mento, incluindo a eliminação,...
Page 157
EGEA 90 LT - 120 LT • A água pode gotejar pelo tubo Ligue o equipamento a um siste- de drenagem do dispositivo ma de ligação à terra eficiente. de sobrepressão; deixe este ATENÇÃO ATENÇÃO tubo aberto para a atmosfera. Não utilizar extensões ou adapta- •...
Page 158
Na falta dessa autorização por escrito, o emprego deve ser referido no cap. “6.9 ESQUEMA considerado “uso impróprio”; portanto a FERROLI S.p.A. de- ELÉTRICO” na página 191 e ATENÇÃO clina qualquer responsabilidade em relação aos danos even- consulte também no interior do...
EGEA 90 LT - 120 LT te as falhas e os danos. emergência. • Respeite os intervalos de manutenção prescritos. ► PERIGO DEVIDO A UMA UTILIZA- ► PERIGO DE MORTE DEVIDO A MU- ÇÃO ERRADA DANÇAS NO PRODUTO OU NO AM- BIENTE DE INSTALAÇÃO Na sequência de um comando errado é...
Page 160
EGEA 90 LT - 120 LT Antes de eliminar o equipamento, deve despejar o refrigerante nele contido num recipiente adequado para ser reciclado ou eliminado nos termos das normas em vigor. Qualquer intervenção no equi- pamento, incluindo a elimi- nação, deve ser realizada por pessoal qualificado e certifi- cado com a adequada Licença em sistemas de refrigeração...
EGEA 90 LT - 120 LT DESTINATÁRIOS DO MANUAL INSTRUÇÕES PARA: Este dirige-se quer ao instalador especializado (instaladores – técnicos de manutenção), quer ao utilizador final. Para distinguir o conteúdo do manual com base nas carate- TÉCNICO ESPECIALISTA / UTILIZADOR rísticas do destinatário (utilizador e técnico especialista), as ASSISTÊNCIA TÉCNICA DO FABRICANTE...
— Símbolos registados. A FERROLI S.p.A. reserva-se o direito de fazer modificações, • UNI EN ISO 7010:2021 - Sinais gráficos - Cores e sinais de alterações ou melhorias no manual ou nas máquinas, a qual- segurança - Sinais de segurança registados...
(REEE). eventuais erros. • Diretiva 2011/65/UE do Parlamento Europeu e do Conselho A FERROLI S.p.A. não se respon- de 8 de junho de 2011 sobre a restrição do uso de cer- sabiliza por danos atribuíveis a tas substâncias perigosas em equipamentos elétricos e erros de operação, uso impró-...
EGEA 90 LT - 120 LT UTILIZAÇÃO DO Limpe apenas a superfície exter- TERMOACUMULADOR na e o painel de controlo com um pano macio e seco. LIMPEZA REGRAS FUNDAMENTAIS DE SEGURANÇA MANUAL Não abra nem desmonte o produ- 2.2.2 Anomalias de funcionamento / falhas to quando este estiver a ser ali- No caso da existência de anomalias de funcionamento, quais- mentado eletricamente.
DA EN 60335-2-40” na página 199. Tecla "aumentar" para aumentar o valor do ponto de definição, parâmetro ou palavra-passe A FERROLI S.p.A. não se respon- Tecla "diminuir" para diminuir o valor do ponto de defini- sabiliza por intervenções realiza- ção, parâmetro ou palavra-passe das por pessoal não especialista...
EGEA 90 LT - 120 LT Durante o funcionamento normal do produto os três dígitos do CONFIGURAÇÃO DO RELÓGIO visor mostram a temperatura da água em °C, medida com a • Com as teclas desbloqueadas, pressione a tecla por 3 se- sonda de água superior se o parâmetro P11 estiver programa- gundos para inserir as configurações do relógio (o sím-...
EGEA 90 LT - 120 LT elétrica, dentro dos limites de funcionamento do produto, para Ponto de definição água quente Modo garantir um aquecimento mais rápido. Range Default A ligação da bomba de calor ocorre 5 minutos após a seleção 38÷62 °C 53 °C AUTOMÁTICO...
EGEA 90 LT - 120 LT No caso de desligamento, dentro dos primeiros 5 minutos, a tado imediatamente aquando da reativação do aparelho após bomba de calor manter-se-á ainda acesa para garantir pelo os dias configurados de ausência. menos 5 minutos de funcionamento contínuo. Parâmetros antilegionela Range Default...
EGEA 90 LT - 120 LT Descarregar e instalar a App "EGEA Smart" Inicie a app "EGEA Smart" no próprio smartphone pressio- nando no ícone conforme supramencionado. Registo do utilizador Para utilizar pela primeira vez a aplicação "EGEA Smart" é necessário o registo do utilizador: crie uma nova conta →...
Page 171
EGEA 90 LT - 120 LT fig. 5 fig. 7 Selecione a rede Wi-Fi e insira a palavra-passe da rede a que Se o procedimento de conexão com o router Wi-Fi for bem- se quer ligar o equipamento e, depois, pressione confirmar na -sucedido, ver-se-á...
Page 172
EGEA 90 LT - 120 LT De seguida, pressione no local correspondente ao símbolo da imagem seguinte. fig. 9 Pressione no local correspondente ao símbolo para sele- cionar, por exemplo, o modo de operação automático. fig. 11 Defina o modo operativo que pretende durante o funcionamen- to por faixas horárias, a hora de ligar e desligar o equipamento e pressione a tecla de confirmação.
Page 173
EGEA 90 LT - 120 LT Quando o funcionamento por faixas horárias estiver ativado, Configure os números dos dias de ausência e pressione con- fora da faixa horária o equipamento está em standby e este é firmar. o ecrã visualizado. fig.
EGEA 90 LT - 120 LT De seguida, pressione confirmar no ecrã seguinte. 2.12 FALHAS/PROTEÇÃO Este equipamento dispõe de um sistema de autodiagnóstico que cobre algumas possíveis falhas ou proteções contra con- dições anómalas de funcionamento através de: deteção, si- nalização e adoção de um procedimento de emergência até...
EGEA 90 LT - 120 LT 2.13 RESOLUÇÃO DE FALHAS Se for constatado que o equipamento não está a funcionar corretamente, sem que haja sinalização de alarme, antes de entrar em contacto com a assistência técnica do fabricante, é conveniente realizar o seguinte. Anomalia Ação aconselhada •...
UTILIZADOR ASSISTÊNCIA TÉCNICA DO FABRICANTE E.P.I. NECESSARIOS: As instruções a seguir destinam-se a pessoal técnico es- pecialista. A FERROLI S.p.A. não se res- ponsabiliza por intervenções realizadas por pessoal não es- ATENÇÃO pecialista e não qualificado. fig. 18 Qualquer intervenção no equi- pamento, incluindo a elimi- REF.ª...
As placas de todos os componentes não construídos direta- Símbolo que identifica o peso da máquina. mente pela FERROLI S.p.A. estão aplicadas diretamente nos Se presente na embalagem, indica o peso de próprios componentes, nos pontos onde os respetivos fabri- cada pacote.
EGEA 90 LT - 120 LT DISPOSITIVOS DE PROTEÇÃO INDIVIDUAL Símbolo Definição O vestuário de quem trabalha ou realiza manutenção deve es- LIMITAÇÃO DE SOBREPOSIÇÃO DAS tar conforme aos requisitos essenciais de segurança definidos EMBALAGENS pelas leis em vigor no país onde o equipamento se encontra Afixado na embalagem indica para não instalado.
EGEA 90 LT - 120 LT MOVIMENTAÇÃO E TRANSPORTE RISCOS RESIDUAIS O projeto foi executado de forma a garantir os requisitos es- MOVIMENTAÇÃO DA EMBALAGEM senciais de segurança para o operador empregado e para o O equipamento é fornecido numa caixa de papelão sobre pa- utilizador final.
EGEA 90 LT - 120 LT CARATERÍSTICAS DE FABRICO RECEÇÃO Além das unidades dentro das embalagens, estão contidos IDENTIFICAÇÃO DOS COMPONENTES também os acessórios e a documentação técnica para a utili- zação e a instalação. REF.ª DESCRIÇÃO (fig. 20 - fig. 21 - fig. 22) •...
EGEA 90 LT - 120 LT INSTALAÇÃO E COLOCAÇÃO EM Ou em aplicações que exigem SERVIÇO um grau superior a IP24 ou que exigem recursos de segurança A instalação, colocação em serviço e manutenção do pro- ATENÇÃO (tolerante a falhas, à prova de duto devem ser realizados por pessoal qualificado e falhas), como sejam, sistemas e autorizado.
EGEA 90 LT - 120 LT 6.3.2 Condições ambientais para funcionamento Na fase de conceção e fabrico dos sistemas devem respeitar-se O equipamento não pode operar as normas e disposições vigen- em locais classificados como OBRIGAÇÃO tes a nível local. ambientes com atmosfera explo- PROIBIÇÃO A entrada e saída de ar do apare-...
EGEA 90 LT - 120 LT FIXAÇÃO NA PAREDE LIGAÇÕES AERÓLICAS O produto deve ser instalado numa parede sólida, não sujeita Além dos espaços indicados no parágrafo, 6.4, a bomba de a vibrações. Para a fixação, escolha o tipo de bucha de ex- calor requer uma ventilação de ar adequada.
EGEA 90 LT - 120 LT LIGAÇÕES HIDRÁULICAS Tubo linear Dado Curva 90° lisa Grelha liso • Ligue a linha de alimentação de água fria e a linha de saída nos pontos de ligação específicos (fig. 33). Tipo Comprimen- to efetivo Comprimen- to equiva- lente...
Page 188
EGEA 90 LT - 120 LT • A água pode gotejar pelo tubo de drenagem do dispositivo de sobrepressão; deixe este ATENÇÃO tubo aberto para a atmosfera. • O dispositivo de descom- pressão deve ser acionado regularmente para remover os depósitos de calcário e para verificar se não está...
EGEA 90 LT - 120 LT Os aparelhos fixos não estão equi- pados com meios de desconexão da rede de alimentação com uma ATENÇÃO separação dos contactos em todos os polos capazes de garantir a des- conexão completa na categoria de sobretensão III, as instruções indicam que os meios de descone- xão devem ser integrados na cabla-...
Page 190
EGEA 90 LT - 120 LT • Digital 3 (DIG3). Entrada para o Off-Peak. Esta função, ape- nas disponível nalguns países, permite ativar o equipamen- to apenas na presença de um sinal proveniente do exterior com tarifa preferencial. Se o contactor elétrico dispõe de um contacto limpo que se fecha quando está...
LIMPEZA MANUAL pelo cliente a um centro de assistência téc- nica autorizado FERROLI S.p.A. no período de garantia convencional para problemas do 6.10.3 Colocação do sistema em serviço produto atribuíveis às configurações erradas • Encha completamente o reservatório usando a torneira de dos parâmetros protegidos por palavra-pas-...
EGEA 90 LT - 120 LT Se a palavra-passe estiver correta, é visualizado o parâmetro P1. Pressione a tecla “+” o valor padrão deste parâmetro é exibido, o qual pode ser modificado pressionando e usando as teclas "+" e "-" é possível alterar o valor dentro da faixa permitida para este parâmetro.
Page 194
EGEA 90 LT - 120 LT Parâmetro Descrição Range Default Notas 0 = EC Tipo de ventilador do evaporador (EC; AC; AC 1 = AC duas velocidades com controlo dinâmico da 2 = AC de duas velocidades Alterável velocidade) 3 = EC com controlo dinâmico da velocidade 0 = NF Tipo de fluxostato de segurança para circuito...
Page 195
EGEA 90 LT - 120 LT Parâmetro Descrição Range Default Notas 0 = não utilizada Utilização EEV Alterável 1 = utilizada Intervalo do cálculo de sobreaquecimento 20÷90s 30 s Alterável para EEV com controlo automático Setpoint de sobreaquecimento para EEV com -8÷15 °C 3 °C Alterável...
Page 196
EGEA 90 LT - 120 LT Parâmetro Descrição Range Default Notas Regulação proporcional da temperatura do 1÷20 °C 4 °C Alterável evaporador da banda 1 Temperatura diferencial com ativação da velo- P57÷20 °C 2 °C Alterável cidade máxima Temperatura diferencial com desativação da 1 °C÷P56 1 °C Alterável...
EGEA 90 LT - 120 LT SUBSTITUIÇÕES SUBSTITUIÇÃO DO FUSÍVEL DA PLACA DE ENERGIA Reparações impróprias podem Proceda conforme indicado de seguida (reservado apenas ao pôr o utilizador em sério peri- pessoal técnico qualificado): go. Se o seu equipamento pre- ATENÇÃO •...
EGEA 90 LT - 120 LT Antes de executar a verificação é necessário: • Fechar a descarga de entrada da água fria. • Proceder ao esvaziamento da água da caldeira (ver pará- grafo “7.4 ESVAZIAMENTO DA CALDEIRA”). • Remova a tampa inferior 1. •...
EGEA 90 LT - 120 LT SUBSTITUIÇÃO DO CABO DE ALIMENTAÇÃO NÃO ADULTERE O CABO DE Não fure nem queime. ALIMENTAÇÃO. OBRIGAÇÃO Se o cabo de alimentação estiver ATENÇÃO danificado, deve ser substituído Preste atenção ao facto de que pelo fabricante ou pelo serviço os fluidos frigorígenos podem de assistência técnica ou, em não ter cheiro.
EGEA 90 LT - 120 LT O produto é desprovido de válvula de carga ou de recarga, pois Certifique-se periodicamente de tal operação não pode nem deve ser executada, por nenhum que não há obstruções nas aber- motivo, no equipamento. Caso se verifique a presença de uma turas destinadas a garantir a re- fuga no circuito frigorífico ou caso o mesmo esteja sem gás novação de ar no interior do lo-...
EGEA 90 LT - 120 LT Deteção de fugas peito pelos regulamentos em vigor. • Não utilize chamas de nenhum tipo para detetar a saída de Antes de proceder à eliminação do produto, é necessário remover gás refrigerante. em segurança o gás refrigerante do circuito, esta operação deve •...
EGEA 90 LT - 120 LT de maneira adequada. Os principais materiais que compõem o equipamento em questão são: • aço - magnésio - plástico - cobre - alumínio - poliuretano INFORMAÇÃO PARA OS UTILIZADORES Nos termos das Diretivas 2011/65/UE e 2012/19/UE relativas à redução do uso de substâncias perigosas em equipa- mentos elétricos e eletrónicos, bem como à...
EGEA 90 LT - 120 LT 11. NOTAS SOBRE OS DISPOSITIVOS RÁDIO E AS APLICAÇÕES Este produto incorpora um módulo de rádio (Wi-Fi) e está em conformidade com a RED (Diretiva de Equipamentos de Rádio) 2014/53/UE. A seguir encontram-se indicados os principais dados da parte rádio: •...
Page 205
Si ce manuel est perdu ou endommagé, une copie supplémen- Pour le centre d’assistance, consulter : taire peut être téléchargée sur www.ferroli.com en sélection- www.ferroli.com nant le produit acheté. Les images sont purement indicatives et ne constituent pas un IDENTIFICATION DE L’APPAREIL...
EGEA 90 L - 120 L CONSIGNES DE SÉCURITÉ Avant d'effectuer tout type d'in- tervention sur l'appareil, le per- sonnel chargé de la maintenance doit se référer aux prescriptions Lire attentivement d’installer et contenues dans ce manuel dans d’utiliser l’appareil. ATTENTION les chapitres suivants, et en par- ticulier à...
EGEA 90 L - 120 L • De l'eau peut s'écouler du Branchez l'équipement à un sys- tuyau d’évacuation du dis- tème de mise à la terre efficace. positif de dépressurisation ; ATTENTION ATTENTION laissez ce tuyau ouvert à l'at- mosphère.
ATTENTION considérée comme une « utilisation non conforme » ; par se référant aussi à l’intérieur du conséquent, FERROLI S.p.A. décline toute responsabilité produit. pour les dommages causés aux biens ou aux personnes et considère comme nulle toute forme de garantie sur la fourni- ture.
EGEA 90 L - 120 L • Faire immédiatement réparer les pannes et les dommages ceptibles de générer des étincelles (par exemple, ne pas par un technicien qualifié. allumer de lumières à partir d'interrupteurs, ne pas bran- • Respecter les intervalles de maintenance prescrits. cher d'appareils électriques, etc.).
EGEA 90 L - 120 L • ne pas inhaler les vapeurs ou les gaz. Consulter immédiatement un médecin en cas de contact avec le réfrigérant. Le réfrigérant ne doit pas être libéré dans l'atmosphère. Avant de mettre l'appareil au rebut, le réfrigérant qu'il contient doit être transvasé...
Page 211
EGEA 90 L - 120 L SOMMAIRE BRUIT ................228 GUIDE POUR : VIBRATIONS ..............228 RISQUES RÉSIDUELS ..........229 4. MANUTENTION ET TRANSPORT ..... 229 MANUTENTION DE L’EMBALLAGE ......229 TECHNICIEN EXPERT / ASSISTANCE UTILISATEUR DÉBALLAGE ..............229 TECHNIQUE DU FABRICANT RÉCEPTION ..............230 1. GÉNÉRALITÉS ........... 212 5.
EGEA 90 L - 120 L DESTINATAIRES DU MANUEL GUIDE POUR : Ce manuel s'adresse à la fois à l'installateur spécialisé (ins- tallateurs - techniciens de maintenance) et à l'utilisateur final. Afin de distinguer le contenu du manuel en fonction des carac- TECHNICIEN EXPERT / ASSISTANCE UTILISATEUR téristiques du destinataire (utilisateur et technicien expert), les...
— Symboles enregistrés. FERROLI S.p.A. se réserve le droit d'apporter des modifica- • UNI EN ISO 7010:2021 - Symboles graphiques - Couleurs tions ou des améliorations au manuel ou à l'appareil à tout de sécurité...
4 juillet 2012 relative aux déchets d'équipements élec- communication s’entend sans préjudice d’erreurs éventuelles. triques et électroniques (DEEE). FERROLI S.p.A. n'est pas respon- • Directive 2011/65/UE du Parlement européen et du Conseil sable des dommages attribuables du 8 juin 2011 relative à la limitation de l'utilisation de cer- à...
EGEA 90 L - 120 L USAGE DU CHAUFFE - EAU Nettoyer uniquement la surface extérieure et le panneau de com- RÈGLES FONDAMENTALES DE SÉCURITÉ mande avec un chiffon doux et NETTOYAGE sec. Ne pas ouvrir et ne pas démonter MANUEL le produit lorsqu'il est alimenté...
D DE LA NORME 60335-2-40» en page 249. paramètre, confirmer ; Touche « Incrémenter » pour augmenter la valeur du FERROLI S.p.A. n'est pas res- point de consigne, le paramètre ou le mot de passe ponsable des travaux effectués Touche « Décrémenter » pour diminuer la valeur du par du personnel non qualifié...
EGEA 90 L - 120 L rétro-éclairées et toutes les icônes et segments de l'écran s'al- PROGRAMMATION DE L’HEURE lument simultanément pendant 3 s. • Avec les touches déverrouillées, appuyer pendant 3 se- Pendant le fonctionnement normal du produit, les trois chiffres condes sur la touche pour entrer les paramètres de de l'écran indiquent la température de l'eau en °C, mesurée...
EGEA 90 L - 120 L Point de consigne eau chaude Mode Dans ce mode, la pompe à chaleur et la résistance électrique Plage Défaut sont utilisées, dans les limites de fonctionnement du produit, 38÷62 °C 53 °C AUTOMATIQUE 38÷62 °C 53 °C pour assurer un chauffage plus rapide.
EGEA 90 L - 120 L duit, pour assurer le meilleur confort possible. Si la demande d'exécution de la fonction anti-légionellose a La pompe à chaleur est mise en marche 5 minutes après avoir lieu avec le mode VACANCES sélectionné, le cycle anti-légio- sélectionné...
EGEA 90 L - 120 L le modèle de chauffe-eau (EGEA mural). Téléchargez et installez l'application "EGEA Smart" Démarrez l'application "EGEA Smart" à partir de votre smart- phone en appuyant sur l'icône comme ci-dessus. Enregistrement des utilisateurs Pour utiliser l'application "EGEA Smart" pour la première fois, l'enregistrement de l'utilisateur est requis : créer un nouveau compte →...
Page 221
EGEA 90 L - 120 L fig. 5 fig. 7 Sélectionnez le réseau Wi-Fi et entrez le mot de passe du ré- Si la procédure de connexion avec le routeur Wi-Fi a réussi, seau auquel vous souhaitez connecter l'appareil, puis appuyez vous verrez votre appareil ajouté...
Page 222
EGEA 90 L - 120 L Appuyez ensuite sur le symbole de l'image suivante. fig. 9 Appuyez sur le symbole pour sélectionner, par exemple, le mode de fonctionnement automatique. fig. 11 Réglez le mode de fonctionnement que vous souhaitez pen- dant le fonctionnement de la plage horaire, l'heure à...
Page 223
EGEA 90 L - 120 L Lorsque le fonctionnement de la plage horaire est activé, Définissez le nombre de jours d'absence et appuyez sur confir- en dehors de la plage horaire, l'appareil est en veille et c'est mer. l'écran affiché. fig.
EGEA 90 L - 120 L Appuyez ensuite confirmer sur l'écran suivant. 2.12 DYSFONCTIONNEMENTS/PROTECTION Cet appareil dispose d'un système d'autodiagnostic qui couvre certaines pannes ou protections éventuelles contre des condi- tions de fonctionnement anormales à travers : la détection, la signalisation et l'adoption d'une procédure d'urgence jusqu'à...
EGEA 90 L - 120 L 2.13 RECHERCHE DES PANNES S'il s'avère que l'appareil ne fonctionne pas correctement, sans signalisation d'alarme, avant de contacter l'assistance technique du fabricant, effectuer les opérations suivantes. Anomalie Action recommandée • Vérifier que la fiche est correctement insérée dans la prise. •...
TECHNICIEN EXPERT / ASSISTANCE UTILISATEUR TECHNIQUE DU FABRICANT E.P.I. NÉCESSAIRES : Les instructions suivantes s’adressent au personnel tech- nique qualifié. FERROLI S.p.A. n'est pas res- ponsable des travaux effec- tués par du personnel non ATTENTION qualifié ou non compétent. Toute intervention sur appa- fig.
Symbole identifiant le poids de la machine. Les plaques signalétiques de tous les composants qui ne sont S’il est présent sur l'emballage, il indique le pas fabriqués directement par FERROLI S.p.A. sont apposées poids de chaque paquet. directement sur les composants à l'endroit où les fabricants respectifs les ont placées à...
EGEA 90 L - 120 L ÉQUIPEMENTS DE PROTECTION INDIVI- Symbole Définition DUELLE LIMITATION DE SUPERPOSITION DES La tenue vestimentaire des personnes chargées de l'exploita- EMBALLAGES tion ou de la maintenance doit être conforme aux exigences Apposé sur le paquet, il indique que les essentielles de sécurité...
EGEA 90 L - 120 L MANUTENTION ET TRANSPORT RISQUES RÉSIDUELS La conception a été réalisée de manière à garantir les exi- MANUTENTION DE L’EMBALLAGE gences essentielles de sécurité pour l'opérateur préposé et L'appareil est livré dans une boîte en carton sur une palette pour l'utilisateur final.
EGEA 90 L - 120 L CARACTÉRISTIQUES DE RÉCEPTION CONSTRUCTION Outre les unités, les emballages contiennent des accessoires et la documentation technique pour l'utilisation et l'installation. IDENTIFICATION DES COMPOSANTS • Contrôler la présence des éléments suivants : - Manuel d'Utilisation, d'Installation et de Maintenance RÉF.
EGEA 90 L - 120 L CARACTÉRISTIQUES TECHNIQUE Modèle 90 L 120 L 230-1-50 Alimentation V-f-Hz Puissance thermique (UNI) Puissance absorbée totale en chauffage (UNI) COP (UNI) 3,08 3,08 1,25 1,25 Courant nominal en chauffage (UNI) Puissance absorbée totale maximum en chauffage 1.74 1.74 Courant maximum en chauffage...
EGEA 90 L - 120 L INSTALLATION ET MISE EN SERVICE Dans des applications nécessi- tant un indice supérieur à IP24 ou L'installation, la mise en service et la maintenance du pro- exigeant des caractéristiques de duit doivent être effectuées par un personnel qualifié ATTENTION sécurité...
EGEA 90 L - 120 L 6.3.2 Conditions environnementales pour le fonctionnement En phase de conception et de fabrication des installations, il L'appareil ne doit pas être utilisé est important de respecter les dans des zones classées comme OBLIGATION normes et dispositions en vi- ayant une atmosphère explosive INTERDICTION gueur au niveau local.
EGEA 90 L - 120 L FIXATION AU MUR CONNEXIONS AÉRAULIQUES Le produit doit être installé sur un mur solide et sans vibrations. La pompe à chaleur nécessite une ventilation adéquate en Pour la fixation, choisissez le type de cheville le plus approprié plus des espaces indiqués au paragraphe 6.4.
EGEA 90 L - 120 L RACCORDEMENTS HYDRAULIQUES Caractéris- Tuyau linéaire Coude 90° Grille lisse lisse tique • Raccorder la canalisation d'alimentation en eau froide et la canalisation de sortie aux points de raccordement appro- priés (fig. 33). Type Longueur effective Longueur équivalente...
EGEA 90 L - 120 L • De l'eau peut s'écouler du tuyau d’évacuation du dis- positif de dépressurisation ; ATTENTION laissez ce tuyau ouvert à l'at- mosphère. • Le dispositif de décompres- sion doit être actionné régu- lièrement pour éliminer les dépôts de calcaire et vérifier qu'il n'est pas bloqué.
EGEA 90 L - 120 L Les équipements fixes ne sont pas équipés de moyens de dé- connexion du réseau d'alimen- ATTENTION tation avec une séparation des contacts sur tous les pôles en mesure d'assurer une décon- nexion complète en catégorie de surtension III, les instruc- tions indiquent que les moyens 60mm...
EGEA 90 L - 120 L • Numérique 3 (DIG3). Entrée pour les heures creuses (Off- Peak). Cette fonction disponible uniquement dans certains pays permet d'activer l'appareil uniquement en présence d'un signal extérieur à tarif réduit. Si le contacteur électrique dispose d’un contact propre qui se ferme lorsque le tarif pré- férentiel est disponible, il est possible de le brancher aux deux conducteurs gris et rose du câble hexapolaire fourni...
Par conséquent, toute intervention demandée Nettoyez uniquement la surface par le client auprès d'un centre d'assistance extérieure à l'aide d'un chiffon technique agréé FERROLI S.p.A. pendant la période de garantie conventionnelle pour doux et sec. NETTOYAGE MANUEL des problèmes attribuables à...
EGEA 90 L - 120 L ce paramètre qui peut être modifiée en appuyant sur « », et avec les touches « + » et « - » il est possible de changer sa valeur dans la plage autorisée pour ce paramètre. Appuyez ensuite sur « »...
Page 244
EGEA 90 L - 120 L Paramètre Description Plage Défaut Remarques 0 = EC Type de ventilateur de l’évaporateur (EC ; AC 1 = AC ; AC deux vitesse ; EC avec contrôle dyna- 2 = AC à deux vitesses Modifiable mique de la vitesse) 3 = EC avec contrôle dyna-...
Page 245
EGEA 90 L - 120 L Paramètre Description Plage Défaut Remarques 0 = non utilisée Utilisation EEV Modifiable 1 = utilisée Intervalle calcul surchauffe pour EEV à 20÷90s 30 s Modifiable contrôle automatique Point de consigne surchauffe pour EEV à -8÷15 °C 3 °C Modifiable...
EGEA 90 L - 120 L Paramètre Description Plage Défaut Remarques Réglage proportionnel température 1÷20 °C 4 °C Modifiable évaporateur bande 1 Température différentielle avec activation de P57÷20°C 2 °C Modifiable la vitesse maximum Température différentielle avec désactivation 1°C÷P56 1 °C Modifiable de la vitesse maximum 0 = OFF...
EGEA 90 L - 120 L REMPLACEMENTS REMPLACEMENT DU FUSIBLE DE LA CARTE D'ALIMENTATION Des réparations incorrectes Procédez comme suit (réservé au personnel technique qualifié peuvent mettre l'utilisateur en uniquement) : danger. Si votre équipement ATTENTION • Débranchez l'alimentation électrique de l'appareil. nécessite réparation, •...
EGEA 90 L - 120 L Avant d'effectuer la vérification, il est nécessaire : • Fermez l'arrivée d'eau froide. • Videz l'eau du chauffe-eau (voir paragraphe « 7.4 VIDANGE DU CHAUFFE-EAU »). • Retirez le capot inférieur 1. • Débranchez la carte de puissance du thermostat de sécurité de la résistance et retirez les sondes à...
EGEA 90 L - 120 L REMPLACEMENT DU CÂBLE D’ALIMENTATION NE PAS MODIFIER LE CÂBLE Ne pas percer ni brûler. D'ALIMENTATION. OBLIGATION Si le câble d'alimentation est en- ATTENTION dommagé, il doit être remplacé Faites attention au fait que les par le fabricant ou par le service fluides réfrigérants peuvent ne d'assistance technique ou par...
EGEA 90 L - 120 L Le produit ne possède pas de valve de remplissage ou de re- Vérifier périodiquement l'ab- charge car cette opération ne peut et ne doit pas être effectuée sence d'obstacles dans les ou- pour quelque raison que ce soit chez l'utilisateur. En cas de vertures destinées à...
EGEA 90 L - 120 L Recherche des fuites plein respect des réglementations en vigueur. • Ne pas utiliser de flammes d'aucune sorte pour détecter la Avant de mettre le produit au rebut, il est nécessaire d'éliminer fuite de gaz réfrigérant. en toute sécurité...
EGEA 90 L - 120 L Les principaux matériaux qui composent l'appareil en question sont : • acier - magnésium - plastique - cuivre - aluminium - polyuréthane INFORMATIONS AUX UTILISATEURS Conformément aux directives 2011/65 / UE et 2012/19 / UE relatives à la réduction de l'utilisation de substances dange- reuses dans les appareils électriques et électroniques, ainsi qu'à...
EGEA 90 L - 120 L 11. NOTES SUR LES DISPOSITIFS RADIO ET APP Ce produit incorpore un module radio (Wi-Fi) et est conforme à la directive RED (Radio Equipment Directive) 2014/53/EU. Nous indiquons ci-dessous les données principales de la partie radio : •...
Page 256
FERROLI S.pA. Via Ritonda 78/a 37047 San Bonifacio - Verona - ITALY www.ferroli.com Fabbricato in Italia - Fabricado en Italia - Made in Italy Fabricado em Itália - Fabriqué en Italie...