Connector J2
Terminal 1 – 230 Vac motor M1 Power supply common
Terminal 2 – 230 Vac motor M1 Power supply common
Terminal 3 – 230 Vac motor M1 Power supply common
Terminal 4 – 230 Vac mains power supply neutral
Important : If the power regulator card is not connected the J2 connector's terminals 3 and 4 must be bridged with 4 mm insulated faston
terminal.
Terminal board J5
Terminal 1 – Aerial cable connection (shield)
Terminal 2 – Aerial cable connection (signal)
Terminal board J3
Terminal 1 - 230 Vac mains power supply phase
Terminal 2 - 230 Vac mains power supply neutral
Warning : The power supply voltage polarities must be carefully observed.

Connection of the devices

230Vac mains power supply cable – Terminals 1 and 2 on J5
Warning: The cable's ground pole must be connected to a good ground reference in the gate's nearby area.
Motor 1 – Terminals 1, 2 and 3 on J1
Motor 2 – Terminals 4, 5 and 6 on J1
Blinker – Terminals 7 and 8 on J1
Electric lock – Terminals 1 and 2 on J4
Photo-cells power supply – Terminals 3 and 4 on J4
NC photo-cell contact – Terminals 5 and 6 on J4
NC photo-stop contact – Terminals 7 and 8 on J4
NO pedestrian start push-button – Terminals 7 and 9 on J4
NO start push-button – Terminals 7 and 10 on J4
Aerial – Terminals 1 and 2 on J3
Important: Before starting the gate check all connections to the electronic card. Check also the electric contacts' switching.