"Condominium" mode
After the power is supplied to the electronic card the first start command determines an opening cycle. At the end of the two work times, the gate
stops. The pause period starts (blinker off). At the end of the pause period the gate closes automatically. The operating cycle is complete only when
the closing motion has ended. If a start command is supplied while the gate opens, the command will have no effect. If a start command is supplied
while the gate closes, the gate will stop and reverse its motion after approx. 1.5 sec. If a start command is supplied during the pause period, the period
will be reset and the automatic closure will start later.
Important : If the gate opening is controlled by a clock the "condominium" mode must be enabled.
In any operation mode, the safety devices causes the following effects :
Photo-cell : This device has effect only during the closure phase or in the pause period. If an obstacle covers the photo-cell during the closure phase,
the gate stops and reverses its motion after approx. 1,5 sec. If an obstacle covers the photo-cell during the pause period this last one is
reset and the automatic closure is therefore delayed.
Photostop : If an obstacle covers the photo-cell during the gate's motion (opening or closure), or during the period preceding the operating cycle's
start, then the gate is temporarily stopped, until the obstacle is not removed. The blinker will light with a fixed light to signal the irregular
condition. When the obstacle is removed and the photocell is freed, an opening cycle will start. If an obstacle covers the photostop
during the pause period this last one is reset and the automatic closure is therefore delayed.
Pedestrian start: The pedestrian start command operates in the same way as the other start command, but in this case only the wing fitted with the
electric lock (M2) will be opened or closed. The pedestrian start command has no effect during a start cycle and up to the end of the
closing phase (closed gate). During a pedestrian start cycle the start command is always active.
F) Electrical and mechanical
Dimensions of electronic card : 140 x 110 x 45 mm
Weight of electronic card : 0,65 Kg
Mains power supply : 230Vac +/- 10%
Stand-by power consumption : approx. 0,5 W
Operating temperature range : 0 to + 60 °C
Single-phase motors power supply : 230Vac 1 HP max
Electric lock power supply : 12 Vac 15 W max
Blinker power supply : 230Vac 40 W max
Accessories power supply : 24Vac 2 W max
Motors' work time : programmable, 1 to 120 sec.
Pause time : programmable, 1 to 250 sec.
Caution : The unit must be not switched on if the connected loads or the power supply exceed the a.m. limits. Failure to observe this precaution can
result in damage to persons, animals or objects for which the manufacturer cannot be held responsible.
characteristics
15
ENGLISH