G) Electric connections
5 electric connectors are fitted to the card :
a) J1 8-pole Terminal board for the connection of the devices operating with 230Vac mains power supply (motors and blinker).
b) J4 10-pole Terminal board for the connection of the devices operating at low voltage (commands, safety devices, 24Vac power supply output and
electric lock).
c) J2 4-pole connector for the optional connection of a power regulator card.
d) J5 2-pole Terminal board for the connection of the mains power supply cable
e) J3 2-pole Terminal board for the connection of the aerial cable
Terminal board J1
Terminal 1 - 230 Vac motor M1 power supply phase (opening)
Terminal 2 - 230 Vac motor M1 power supply phase (closure)
Terminal 3 - 230 Vac motor M1 power supply neutral (common)
Note: connect the capacitor of the motor M1 between terminals 1 and 2.
Terminal 4 - 230 Vac motor M2 power supply phase (opening)
Terminal 5 - 230 Vac motor M2 power supply phase (closure)
Terminal 6 - 230 Vac motor M2 power supply neutral (common)
Note: connect the capacitor of the motor M1 between terminals 4 and 5.
Terminal 7 - 230 Vac blinker power supply phase
Terminal 8 - 230 Vac blinker power supply neutral (common)
Terminal board J4
Terminal 1 - Electric lock 12Vac power supply
Terminal 2 - Electric lock 12Vac power supply (common)
Terminal 3 - 24Vac power supply for photo-cells or other devices (Common)
Terminal 4 - 24Vac power supply for photo-cells or other devices
Terminal 5 - Photo-cell's normally closed electric contact (Common)
Terminal 6 - Photo-cell's normally closed electric contact
Terminal 7 - Common terminal for all electric contacts of Start and photo-stop
Terminal 8 - Photo-stop's normally closed electric contact
Terminal 9 - Pedestrian start push-button's normally open electric contact
Terminal 10 - Start push-button's normally open electric contact
Important : The normally closed inputs not in use must be fitted with jumpers