Clean Air; Sufficient Volume Of Air; Adjusting Air Pressure; Amount Of Product To Be Applied - Sagola 4500 XTREME Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 67
24/25
Close the product regulator until the appropriate
amount of product comes out. Now you have the
maximum spraying width (spraying pattern). You
can reduce this according to your needs by closing
the spray width regulator.
OK
Please be sure that you put the spray gun properly
by keeping its perpendicularity to the piece to be
painted in order to achieve the maximum transfer
of the sprayed product and obtain the best finishing
quality.

11.1.- Clean Air

The air used for spraying must reach the gun free of impurities, aerosols, oil, silicone and solid
particles. To do this you must eliminate these with coalescent filter units.
The use of air treatment equipment with built-in pressure regulators is recommended (Models
SAGOLA 5200, 5300 or 5300 Plus).

11.2. Sufficient volume of air

A sufficient volume of air can be supplied to the gun by means of an air compressor of adequate
power (1HP equals 110 L/min approximately), a good compressed air network and by avoiding
pressure drops through the use of antistatic, silicon-free air hoses with a minimum inside
diameter of 8 mm. and resistant to the spraying air pressure (minimum 20 bar) and to the
aggressive effects of paint solvents. Before assembling the air network, you must check on the
air tightness of the hose.
Use antistatic air hoses. Should an antistatic air hose not be available, you must attach the unit
to a ground connection in order to eliminate any static electricity.
The total derivative resistance must be <100 million ohms.

11.3. Adjusting Air Pressure

11.3.1.Digital Pressure Gauge Version

The gun leaves the factory ready to work at an input pressure of 2 bar. In
order to change this adjustment, turn the flow regulator clockwise until the
pressure indicated in the internal pressure gauge coincides with the
required working pressure.

11.3.2.- Analogue Pressure Gauge Version

The gun leaves the factory ready to work at an input pressure of 2 bar. In
order to change this adjustment, turn the regulator control clockwise in
order to reduce the pressure and anticlockwise to increase this, until the
pressure indicated in the pressure gauge coincides with the required
working pressure.

11.3.3.- Version without Pressure Gauge

The gun leaves the factory with the internal flow regulator fully open. In
order to adjust this to the required pressure, turn the regulator clockwise to
reduce the inlet pressure and anticlockwise to increase this.

11.4. Amount of Product to be applied

Once the product to be applied has been adequately diluted, turn the
Product Regulator clockwise to reduce the amount of product and anticloc-
kwise to increase this.
During application, the amount of product applicable in areas that are
small or difficult to access can be reduced by reducing the pressure
applied with one's finger.