22 | English
Infra-red thermometer
Recommended chargers
A) Plus use-dependent deviation (e.g. reflection, distance, ambient temperature)
B) At an ambient temperature of +20 °C to +23 °C, an emissivity of > 0.999, measuring distance of 0.3 m, aperture of 60 mm
C) At an ambient temperature of +15 °C to +40 °C
D) Values in accordance with the Association of German Engineers' VDI/VDE 3511 part 4.3 standard (publication date July 2005); applies for
90 % of the measuring signal.
In all areas beyond the values detailed in the technical data, deviations are possible in measurement readings.
E) Refers to infrared measurement, see figure:
F) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
G) Depends on battery in use
H) When using Bluetooth® Low Energy devices, it may not be possible to establish a connection depending on the model and operating system.
Bluetooth® devices must support the SPP profile.
The serial number (6) on the type plate is used to clearly identify your measuring tool.
Assembly
Measuring Tool Power Supply
The measuring tool can be operated either with conventional
non-rechargeable batteries or with a Bosch lithium-ion bat-
tery.
Operation with non-rechargeable batteries (see figure B)
The batteries are inserted into the battery adapter.
The battery adapter is intended only for use in desig-
u
nated Bosch measuring tools and must not be used
with power tools.
Always replace all the batteries at the same time. Only use
batteries from the same manufacturer and which have the
same capacity.
Take the batteries out of the measuring tool when you
u
are not using it for a prolonged period of time. The bat-
teries can corrode and self-discharge during prolonged
storage in the measuring tool.
Operation with rechargeable battery pack (see figure C)
Use only the chargers listed in the technical data. Only
u
these chargers are matched to the lithium-ion battery of
your measuring tool.
Note: The use of batteries unsuitable for your measuring tool
can lead to malfunctions or damage to the measuring tool.
Note: The battery is supplied partially charged. To ensure
full capacity of the battery, completely charge the battery
before the first use.
The lithium-ion battery can be charged at any time without
reducing its service life. Interrupting the charging process
does not damage the battery.
1 609 92A 4X3 | (03.11.2020)
1 m
2 m
Operation
Starting Operation
Protect the measuring tool from moisture and direct
u
sunlight.
Do not expose the measuring tool to any extreme tem-
u
peratures or variations in temperature. For example,
do not leave it in a car for extended periods of time. In
case of large variations in temperature, allow the measur-
ing tool to adjust to the ambient temperature before put-
ting it into operation. The precision of the measuring tool
may be compromised if exposed to extreme temperat-
ures or variations in temperature.
Make sure that the measuring tool is correctly accli-
u
matised. In case of large variations in temperature, accli-
matisation can take up to 60 minutes. This may be the
case, for example, if you store the measuring tool in a cool
car and then perform a measurement in a warm building.
Avoid hard knocks to the measuring tool or dropping
u
it. After severe external influences and in the event of ab-
normalities in the functionality, you should have the
measuring tool checked by an authorised Bosch after-
sales service agent.
Switching on/off
Take the protective cap (21) off the infrared reception
lens (23) and the protective cap (19) off the humidity and
ambient temperature sensor (5). Make sure that the
camera (22), reception lens (23) and sensor (5) are not
closed or covered when working, as this will affect the
accuracy of the measurements taken.
To switch on the measuring tool, press the on/off
button (12) or the measure button (4). A start sequence will
GIS 1000 C
GAL 12...
5 m
Bosch Power Tools