8. Dismounting, return and disposal / 9. Specifications
When returning the instrument, use the original packaging or a suitable transport
packaging.
To avoid damage:
EN
1. Place the instrument, along with shock-absorbent material, in the packaging.
Place shock-absorbent material evenly on all sides of the transport packaging.
2. If possible, place a bag containing a desiccant inside the packaging.
3. Label the shipment as carriage of a highly sensitive measuring instrument.
Information on returns can be found under the heading "Service" on our local
website.
8.3 Disposal
Incorrect disposal can put the environment at risk.
Dispose of instrument components and packaging materials in an environmentally
compatible way and in accordance with the country-specific waste disposal regulations.

9. Specifications

Specifications
Nominal size
Scale range
Working range
Case
Model A43.10
Model A43.20
Model A43.30
Process connection
Stem
Thermowell
Permissible operating pressure at
thermowell
Indication accuracy
Indication correction
Scale angle
18
Model A43
63, 80, 100
-30 ... +50 °C to 0 ... 120 °C
Full scale value
Aluminium
Steel, galvanised
Plastic, black
Thermowell G ½ B, brass
Aluminium
Brass
Max. 6 bar
Class 2 per EN 13190
At bottom of stem
aprox. 270°
WIKA operating instructions bimetal thermometers for HVAC